Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
AutoPIPE
  • Product Communities
AutoPIPE
AutoPIPE Wiki Critical and High issues released in AutoPIPE CONNECT v.12.08
    • Sign In
    • -Pipe and Vessel Stress Analysis - Wiki
      • -.Bentley AutoPIPE
        • +a. General Information about AutoPIPE
        • +b. NEW User Guide for AutoPIPE
        • +c. Technical Support - AutoPIPE
        • +d. Download - Install - Release Notes - AutoPIPE
        • -e. Features and Bugs in AutoPIPE
          • -01.Critical and High issues logged in AutoPIPE:
            • -Critical and High issues fixed and released in version of AutoPIPE:
              • Critical and High issues released in AutoPIPE 2004 v.08.05..
              • Critical and High issues released in AutoPIPE 2004 v.08.06..
              • Critical and High issues released in AutoPIPE 5.x and lower
              • Critical and High issues released in AutoPIPE 6.0 - 6.3
              • Critical and High issues released in AutoPIPE CONNECT v.10.00
              • +Critical and High issues released in AutoPIPE CONNECT v.10.01
              • +Critical and High issues released in AutoPIPE CONNECT v.11.00.00
              • +Critical and High issues released in AutoPIPE CONNECT v.11.01.00
              • +Critical and High issues released in AutoPIPE CONNECT v.11.03
              • +Critical and High issues released in AutoPIPE CONNECT v.11.04
              • +Critical and High issues released in AutoPIPE CONNECT v.12.00
              • +Critical and High issues released in AutoPIPE CONNECT v.12.01
              • +Critical and High issues released in AutoPIPE CONNECT v.12.02
              • +Critical and High issues released in AutoPIPE CONNECT v.12.03
              • +Critical and High issues released in AutoPIPE CONNECT v.12.04
              • Critical and High issues released in AutoPIPE CONNECT v.12.06
              • Critical and High issues released in AutoPIPE CONNECT v.12.07
              • -Critical and High issues released in AutoPIPE CONNECT v.12.08
                • AutoPIPE known issue - defect 732630
                • AutoPIPE known issue - defect 781999
                • AutoPIPE known issue - defect 794182
              • +Critical and High issues released in AutoPIPE V8i v.09.01..
              • Critical and High issues released in AutoPIPE V8i v.09.02..
              • +Critical and High issues released in AutoPIPE V8i v.09.03..
              • Critical and High issues released in AutoPIPE V8i v.09.04..
              • +Critical and High issues released in AutoPIPE V8i v.09.05..
              • +Critical and High issues released in AutoPIPE V8i v.09.06..
              • Critical and High issues released in AutoPIPE XM v.08.09..
              • Critical and High issues released in AutoPIPE XM v.09.00..
            • +Critical and High issues introduced in AutoPIPE
            • Is my AutoPIPE model affected by a known issue?
          • +02. Featured and Bugs Logged for AutoPIPE
          • 03. QA Error Reports for AutoPIPE
          • 04. AutoPIPE's Most Wanted...
        • +f. License AutoPIPE -
        • +g. System Messages: Warnings, Errors, Crashed, Confirm, etc.. in AutoPIPE
        • h. QA&R program for AutoPIPE
        • i. Security
        • +❤︎ Support Solutions and FAQ's in AutoPIPE
      • +.Bentley AutoPIPE Vessel (powered by Microprotol)
      • +ADL PIPE
      • +Bentley AutoPIPE Nozzle
      • +Bentley PlantFLOW
      • +Bentley PULS
    • +AutoPIPE Brand Learning Resources
    • +Attend a live meeting with an AutoPIPE Analyst

     
     Questions about this article, topic, or product? Click here. 

    Critical and High issues released in AutoPIPE CONNECT v.12.08

    Items fixed in this version of the application 12.08.01

    891921
     Modifying Pressure/Temperature data of one point, modifies Pressure/Temperature data of other point(s)
    Workaround: Perform round trip on the model.

    Items fixed in this version of the application 12.08.00.063

    801331
     Soil ID input grid: PGV value cannot be modified, instead of PGV the PGA value is updated
    794182
     Flange Check: Auto Flange/Bolt Dimensions box incorrectly resets gasket material and configuration
    781999
     Time history Location dialog does not accept beam nodes
    761529
     B31.3 and B31.12 IP: Override SIF checkbox for SIFs in the 'Joint Type and User SIFs' dialog does not use 0.75i condition
    732630
     Max Ratio for flange with ANSI check is displayed incorrectly in the Flange Summary report

    See Also

    Critical issues released in version

    Bentley AutoPIPE

    • critical
    • 12.08
    • AutoPIPE
    • bug
    • Known Issues
    • High
    • feature
    • Released in Version
    • Share
    • History
    • More
    • Cancel
    • Mike Dattilio Created by Bentley Colleague Mike Dattilio
    • When: Mon, Apr 18 2022 12:15 PM
    • Mike Dattilio Last revision by Bentley Colleague Mike Dattilio
    • When: Wed, Mar 15 2023 6:56 PM
    • Revisions: 8
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies