<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>28. % of Operating - Earthquake /  Motion / Wind setting on the Load Conditions tab if the Vessel dialog in AutoPIPE Vessel</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/63242/28-of-operating---earthquake-motion-wind-setting-on-the-load-conditions-tab-if-the-vessel-dialog-in-autopipe-vessel</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>28. % of Operating - Earthquake /  Motion / Wind setting on the Load Conditions tab if the Vessel dialog in AutoPIPE Vessel</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/63242/28-of-operating---earthquake-motion-wind-setting-on-the-load-conditions-tab-if-the-vessel-dialog-in-autopipe-vessel</link><pubDate>Wed, 01 Feb 2023 16:42:38 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:bd7e671d-32cd-4abb-be11-b82b8c351035</guid><dc:creator>Mike Dattilio</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/63242/28-of-operating---earthquake-motion-wind-setting-on-the-load-conditions-tab-if-the-vessel-dialog-in-autopipe-vessel#comments</comments><description>Current Revision posted to AutoPIPE Wiki by Mike Dattilio on 2/1/2023 4:42:38 PM&lt;br /&gt;
&lt;p style="margin-left:0px;padding-left:30px;"&gt;&lt;strong&gt;&lt;span style="background-color:#008000;color:#ffffff;font-size:150%;"&gt;&lt;span style="font-size:x-large;"&gt;Answer:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p style="padding-left:90px;"&gt;&lt;span style="background-color:#ffff00;"&gt;% of Operating - Motion&lt;/span&gt;&lt;/p&gt;
&lt;p style="padding-left:120px;"&gt;If checked, the field is enabled. The motion applied for the case is a percentage of the motion in operating conditions. By default 100%. &lt;strong&gt;Disabled for operating case.&lt;/strong&gt;&lt;/p&gt;
&lt;p style="padding-left:90px;"&gt;&lt;span style="background-color:#ffff00;"&gt;% of Operating - Earthquake&lt;/span&gt;&lt;/p&gt;
&lt;p style="padding-left:120px;"&gt;If checked, the field is enabled. The earthquake applied for the case is a percentage of the earthquake in operating conditions. By default 100%. &lt;strong&gt;Disabled for operating case.&lt;/strong&gt;&lt;/p&gt;
&lt;p style="padding-left:120px;"&gt;Note:&lt;/p&gt;
&lt;p style="padding-left:150px;"&gt;Starting in AutoPIPE 43.01.01.011 for operating&amp;nbsp;&lt;/p&gt;
&lt;p style="padding-left:150px;"&gt;The program should never have allowed the user to make modifications to the % of operating&amp;quot; setting for Case = operating. This should have always been unchecked and set to 100 % behind the scene. Again, the new version is the correct way for Case = operating, while the previous versions were wrong.&lt;/p&gt;
&lt;p style="padding-left:150px;"&gt;Unfortunately there is no&amp;nbsp;possibility to apply a percentage on Wind/Earthquake in operating condition. A workaround is to define different Wind and Earthquake settings for each conditions.&lt;/p&gt;
&lt;p style="padding-left:150px;"&gt;For example, for Wind loads:&lt;br /&gt;In Operating condition, input a dynamic pressure taking into account a percentage: e.g. 100 daN/m&amp;sup2; * 0.9 = 90 daN/m&amp;sup2;&lt;br /&gt;In Shutdown condition, uncheck the percentage, open the Wind dialog and input a dynamic pressure taking into account a different percentage: e.g. 100 daN/m&amp;sup2;*0.7 = 70 daN/m&amp;sup2;&lt;br /&gt;Repeat this procedure for all study cases&lt;/p&gt;
&lt;p style="padding-left:150px;"&gt;&lt;/p&gt;
&lt;p style="padding-left:90px;"&gt;&lt;span style="background-color:#ffff00;"&gt;% of Operating - Wind&lt;/span&gt;&lt;/p&gt;
&lt;p style="padding-left:120px;"&gt;If checked, the field is enabled. The wind applied for the case is a percentage of the wind in operating conditions. By default 100%. &lt;strong&gt;Disabled for the operating case.&lt;/strong&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: % of Operating, motion, earthquake, Wind&lt;/div&gt;
</description></item><item><title>28. % of Operating - Earthquake /  Motion / Wind setting on the Load Conditions tab if the Vessel dialog in AutoPIPE Vessel</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/63242/28-of-operating---earthquake-motion-wind-setting-on-the-load-conditions-tab-if-the-vessel-dialog-in-autopipe-vessel/revision/3</link><pubDate>Mon, 21 Nov 2022 19:45:18 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:bd7e671d-32cd-4abb-be11-b82b8c351035</guid><dc:creator>Mike Dattilio</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/63242/28-of-operating---earthquake-motion-wind-setting-on-the-load-conditions-tab-if-the-vessel-dialog-in-autopipe-vessel#comments</comments><description>Revision 3 posted to AutoPIPE Wiki by Mike Dattilio on 11/21/2022 7:45:18 PM&lt;br /&gt;
&lt;p style="margin-left:0px;padding-left:30px;"&gt;&lt;strong&gt;&lt;span style="background-color:#008000;color:#ffffff;font-size:150%;"&gt;&lt;span style="font-size:x-large;"&gt;Answer:&lt;/span&gt;&lt;/span&gt;&lt;/strong&gt;&lt;/p&gt;
&lt;p style="padding-left:90px;"&gt;&lt;span style="background-color:#ffff00;"&gt;% of Operating - Motion&lt;/span&gt;&lt;/p&gt;
&lt;p style="padding-left:120px;"&gt;If checked, the field is enabled. The motion applied for the case is a percentage of the motion in operating conditions. By default 100%. &lt;strong&gt;Disabled for operating case.&lt;/strong&gt;&lt;/p&gt;
&lt;p style="padding-left:90px;"&gt;&lt;span style="background-color:#ffff00;"&gt;% of Operating - Earthquake&lt;/span&gt;&lt;/p&gt;
&lt;p style="padding-left:120px;"&gt;If checked, the field is enabled. The earthquake applied for the case is a percentage of the earthquake in operating conditions. By default 100%. &lt;strong&gt;Disabled for operating case.&lt;/strong&gt;&lt;/p&gt;
&lt;p style="padding-left:90px;"&gt;&lt;span style="background-color:#ffff00;"&gt;% of Operating - Wind&lt;/span&gt;&lt;/p&gt;
&lt;p style="padding-left:120px;"&gt;If checked, the field is enabled. The wind applied for the case is a percentage of the wind in operating conditions. By default 100%. &lt;strong&gt;Disabled for the operating case.&lt;/strong&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: % of Operating, motion, earthquake, Wind&lt;/div&gt;
</description></item><item><title>28. % of Operating - Earthquake /  Motion / Wind setting on the Load Conditions tab if the Vessel dialog in AutoPIPE Vessel</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/63242/28-of-operating---earthquake-motion-wind-setting-on-the-load-conditions-tab-if-the-vessel-dialog-in-autopipe-vessel/revision/2</link><pubDate>Mon, 21 Nov 2022 19:43:14 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:bd7e671d-32cd-4abb-be11-b82b8c351035</guid><dc:creator>Mike Dattilio</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/63242/28-of-operating---earthquake-motion-wind-setting-on-the-load-conditions-tab-if-the-vessel-dialog-in-autopipe-vessel#comments</comments><description>Revision 2 posted to AutoPIPE Wiki by Mike Dattilio on 11/21/2022 7:43:14 PM&lt;br /&gt;
&lt;h4 style="padding-left:60px;"&gt;&lt;span style="text-decoration:underline;"&gt;&lt;strong&gt;Answer:&amp;nbsp;&lt;/strong&gt;&lt;/span&gt;&lt;/h4&gt;
&lt;p style="padding-left:120px;"&gt;&lt;span style="background-color:#ffff00;"&gt;% of Operating - Motion&lt;/span&gt;&lt;/p&gt;
&lt;p style="padding-left:150px;"&gt;If checked, the field is enabled. The motion applied for the case is a percentage of the motion in operating conditions. By default 100%. &lt;strong&gt;Disabled for operating case.&lt;/strong&gt;&lt;/p&gt;
&lt;p style="padding-left:120px;"&gt;&lt;span style="background-color:#ffff00;"&gt;% of Operating - Earthquake&lt;/span&gt;&lt;/p&gt;
&lt;p style="padding-left:150px;"&gt;If checked, the field is enabled. The earthquake applied for the case is a percentage of the earthquake in operating conditions. By default 100%. &lt;strong&gt;Disabled for operating case.&lt;/strong&gt;&lt;/p&gt;
&lt;p style="padding-left:120px;"&gt;&lt;span style="background-color:#ffff00;"&gt;% of Operating - Wind&lt;/span&gt;&lt;/p&gt;
&lt;p style="padding-left:150px;"&gt;If checked, the field is enabled. The wind applied for the case is a percentage of the wind in operating conditions. By default 100%. &lt;strong&gt;Disabled for the operating case.&lt;/strong&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: % of Operating, motion, earthquake, Wind&lt;/div&gt;
</description></item><item><title>28. % of Operating - Earthquake /  Motion / Wind setting on the Load Conditions tab if the Vessel dialog in AutoPIPE Vessel</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/63242/28-of-operating---earthquake-motion-wind-setting-on-the-load-conditions-tab-if-the-vessel-dialog-in-autopipe-vessel/revision/1</link><pubDate>Mon, 21 Nov 2022 19:42:25 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:bd7e671d-32cd-4abb-be11-b82b8c351035</guid><dc:creator>Mike Dattilio</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/63242/28-of-operating---earthquake-motion-wind-setting-on-the-load-conditions-tab-if-the-vessel-dialog-in-autopipe-vessel#comments</comments><description>Revision 1 posted to AutoPIPE Wiki by Mike Dattilio on 11/21/2022 7:42:25 PM&lt;br /&gt;
&lt;h4&gt;&lt;span style="text-decoration:underline;"&gt;&lt;strong&gt;Answer:&amp;nbsp;&lt;/strong&gt;&lt;/span&gt;&lt;/h4&gt;
&lt;p style="padding-left:60px;"&gt;&lt;span style="background-color:#ffff00;"&gt;% of Operating - Motion&lt;/span&gt;&lt;/p&gt;
&lt;p style="padding-left:90px;"&gt;If checked, the field is enabled. The motion applied for the case is a percentage of the motion in operating conditions. By default 100%. &lt;strong&gt;Disabled for operating case.&lt;/strong&gt;&lt;/p&gt;
&lt;p style="padding-left:60px;"&gt;&lt;span style="background-color:#ffff00;"&gt;% of Operating - Earthquake&lt;/span&gt;&lt;/p&gt;
&lt;p style="padding-left:90px;"&gt;If checked, the field is enabled. The earthquake applied for the case is a percentage of the earthquake in operating conditions. By default 100%. &lt;strong&gt;Disabled for operating case.&lt;/strong&gt;&lt;/p&gt;
&lt;p style="padding-left:60px;"&gt;&lt;span style="background-color:#ffff00;"&gt;% of Operating - Wind&lt;/span&gt;&lt;/p&gt;
&lt;p style="padding-left:90px;"&gt;If checked, the field is enabled. The wind applied for the case is a percentage of the wind in operating conditions. By default 100%. &lt;strong&gt;Disabled for the operating case.&lt;/strong&gt;&lt;/p&gt;&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: % of Operating, motion, earthquake, Wind&lt;/div&gt;
</description></item></channel></rss>