Applies To | |||
Product: | AutoPIPE | ||
Severity: | High | ||
First Affected Version: | 12.03 | ||
Fixed and Released in Version: | 12.08.00.063 |
Flange Check: Auto Flange/Bolt Dimensions box incorrectly resets gasket material and configuration
A bug was introduced in the Flange Check dialog along with the new Auto Flange/BoltDimensions checkbox, causing “Gasket materials” and “Gasket Configurations” tobe reset to SPIRAL-WOUND ALLOY WITH MINERAL FIBER FILL and configuration Sketch 1(a), respectively when:
* Auto Flange/Bolt Dimensions checkbox checked
* Auto Flange/Bolt Dimensions checkbox checked and the dialog closed and opened again
* Clicking OK on Flange Check dialog, all gaskets whoseflange used Auto Flange/Bolt Dimensions checkbox would have both of these properties reset.
Make the required changes to the gasket properties, then run the analysis without closing the dialog. Gasket properties will need to be updated each time the dialog is opened while the Auto Flange/Bolt Dimensions checkbox is checked.
Program should retain all Gasket tab settings for flange check including “Gasket materials” and “Gasket Configurations” regardless of Auto Flange/Bolt Dimensions checkbox state and/or closing/re-opening of flange check dialog.
Critical and High issues released in AutoPIPE CONNECT v.12.08