AutoPIPE known issue - defect 794182


Applies To
 Product:AutoPIPE
Severity: High
First Affected Version:12.03
Fixed and Released in Version:12.08.00.063

Title

Flange Check: Auto Flange/Bolt Dimensions box incorrectly resets gasket material and configuration

Reported Description

A bug was introduced in the Flange Check dialog along with the new Auto Flange/BoltDimensions checkbox, causing “Gasket materials” and “Gasket Configurations” tobe reset to SPIRAL-WOUND ALLOY  WITH MINERAL FIBER FILL and configuration Sketch 1(a), respectively when:
* Auto Flange/Bolt Dimensions checkbox checked
* Auto Flange/Bolt Dimensions checkbox checked and the dialog closed and opened again
* Clicking OK on Flange Check dialog, all gaskets whoseflange used Auto Flange/Bolt Dimensions checkbox would have both of these properties reset.

Avoidance

Make the required changes to the gasket properties, then run the analysis without closing the dialog. Gasket properties will need to be updated each time the dialog is opened while the Auto Flange/Bolt Dimensions checkbox is checked. 

Solution:

Program should retain all Gasket tab settings for flange check including “Gasket materials” and “Gasket Configurations” regardless of Auto Flange/Bolt Dimensions checkbox state and/or closing/re-opening of flange check dialog. 

Also See:

Critical and High issues released in AutoPIPE CONNECT v.12.08 

Fixed and Released In Version 

First Affected Version