AutoPIPE known issue - defect 781999


Applies To
 Product:AutoPIPE
Severity: High
First Affected Version:09.05
Fixed and Released in Version:12.08.00.063

Title

Time history Location dialog does not accept beam nodes

Reported Description

The user is able to create a THP (Time History Profile) without any issue. However, if one was to apply a different THP to different location on a pipe, just need to enter the node point name. When trying to assign a different profile to different beam nodes the following appears "Point not found" 

Avoidance

Manually manipulate the THL (Time History Location) file. 

Solution:

Program should allow user to add beam nodes in time history location dialog. 

Also See:

Critical and High issues released in AutoPIPE CONNECT v.12.08 

Fixed and Released In Version 