Applies To | |||
Product: | AutoPIPE | ||
Severity: | High | ||
First Affected Version: | 09.05 | ||
Fixed and Released in Version: | 12.08.00.063 |
Time history Location dialog does not accept beam nodes
The user is able to create a THP (Time History Profile) without any issue. However, if one was to apply a different THP to different location on a pipe, just need to enter the node point name. When trying to assign a different profile to different beam nodes the following appears "Point not found"
Manually manipulate the THL (Time History Location) file.
Program should allow user to add beam nodes in time history location dialog.
Critical and High issues released in AutoPIPE CONNECT v.12.08