AutoPIPE known issue - defect 732630


Applies To
 Product:AutoPIPE
Severity: High
First Affected Version:11.04
Fixed and Released in Version:12.08.00.063

Title

Max Ratio for flange with ANSI check is displayed incorrectly in the Flange Summary report

Reported Description

For any ANSI enabled flange, Max. ratio is the maximum pressure ratio selected from multiple load combinations under 'ANSI Flange Check'. This ratio is reported in the Flange Summary report section generated using Output Reports (Result > Quick Reports > Output Report). The program was reporting this maximum ratio incorrectly e.g.  

(1) When there are two flanges on the same point and only the second flange is ANSI enabled, the program reported a 'Zero' max ratio for the ANSI flange. In some cases, there is an incorrect non-zero value reported.

(2) When there are two flanges on the same point and both the flanges are ANSI enabled, the program reported the correct max ratio value for the first flange and incorrect max ratio for the 2nd flange as a duplicate of 1st flange.

Avoidance

The highest value of pressure ratio can be read from the ANSI Flange Check report for ANSI-enabled flanges. 

Solution:

The program should report the correct value of Max Ratio for flanges with ANSI check in the Flange Summary report 