Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
AutoPIPE
  • Product Communities
AutoPIPE
AutoPIPE Wiki 03. The program do not finish the calculation
    • Sign In
    • -Pipe and Vessel Stress Analysis - Wiki
      • +.Bentley AutoPIPE
      • -.Bentley AutoPIPE Vessel (powered by Microprotol)
        • +Features and Bugs
        • +General Information
        • -Support Solutions and FAQ's
          • +Air Coolers
          • Boilers
          • -Calculations
            • +A. As Per BS EN 13445-3
            • +B. As Per ASME Section VIII
            • +C. As Per CODAP
            • D. PD 5500
            • +E. AD 2000-Merkblatter
            • -F. General
              • 01. Why there are significantly higher values in wind loading in some particular sections of vessels despite the model no platforms / ladders or other equipment?
              • 02. How to check for bolt load calculations for longitudinal saddle load generated during bundle pullout?
              • 03. The program do not finish the calculation
              • 04. How to calculate the tensile stress in bolts of an AutoPIPE Vessel model?
              • 05. Allowable stresses input by user for test conditions in AutoPIPE Vessel
              • 06. The Calculation Strength command or button is grayed out, How to resolve this in AutoPIPE Vessel?
              • 07. Error in the calculation of yC: yC = m + E + m + H/2 in the edition of the results
              • 08. When I select a component and click on "Show Selected Report Calculation Details", nothing seems to happen. What is the solution?
              • 09. Why does the AutoPIPE Vessel calculate different wall thickness for a vertical vessel where one chamber is made with 2 sections of the same material?
              • 10. Rounding Error - value of pi
              • 11. Results are different when using different versions of AutoPIPE Vessel
              • 12. Longitudinal loads on saddles
              • 13. How are the RAHL values calculated? When do the sliding saddles start to move in AutoPIPE Vessel?
              • 14. Obtaining foundation load in AutoPIPE Vessel
              • 15. How do I analyze a rectangular vessel attachment or wear plate?
              • 16. How to perform calculations for test case in AutoPIPE Vessel?
              • 17. Execute > View Calculation Results command not working
              • 18. The "Period" is calculated by what method in AutoPIPE Vessel?
              • 19. Why saddle support reactions are 0.00 in an AutoPIPE Vessel output report?
              • 20. How do you analyze a head with a skirt smaller than the diameter of the head?
              • 21. How AutoPipe vessel takes care of Saddle if its placed on Transition element like Cone?
              • 22. Consequence of the input of the elevation in the dialog of the bracket or ring in AutoPIPE Vessel?
              • 23. Why reactions at the bracket support are not matching with the hand calculations?
              • 24. Limpet Coil Moment of Inertia calculation verification using AutoPIPE Vessel and Microstation
          • +Coils
          • +Cost Estimation
          • +Drawings
          • +Expansion Joints
          • +Import / Export
          • +Interface
          • +Lifting Lugs
          • +Loads and Load Combinations
          • +Material, Material Database, and Default Libraries
          • +Nozzles and Flanges
          • +Pressure Vessels
          • +Report
          • +Shell and Tube Heat Exchangers
          • +Shells
          • +Soil
          • +Tanks
          • +Units
          • +Vortex Shedding
          • +Weld Joints
        • +System Messages
        • +Video Gallery
      • +ADL PIPE
      • +Bentley AutoPIPE Nozzle
      • +Bentley PlantFLOW
      • +Bentley PULS
    • +AutoPIPE Brand Learning Resources
    • +Attend a live meeting with an AutoPIPE Analyst

     
     Questions about this article, topic, or product? Click here. 

    03. The program do not finish the calculation

    Applies To
    Product(s): AutoPIPE Vessel
    Version(s): ALL
    Area: General
    Date Logged
    & Current Version
    June 2023
    41.01.01.011

    Problem:

    The program do not finish the calculation

    Solution:

    This could be happen due to wrong or incomplete modelling of the equipment, Few of the reason could be as follows,

    1. Incorrect modelling of heat exchanger type / components

    2. Channel head missing in the model

    3. Not enough component added with respect to the type of heat exchanger

    See Also

    AutoPIPE Vessel

    Bentley LEARN Server

    • AutoPIPE Vessel
    • Calculation
    • Share
    • History
    • More
    • Cancel
    • Tanaji Gaikwad Created by Bentley Colleague Tanaji Gaikwad
    • When: Mon, Jun 12 2023 9:35 AM
    • Tanaji Gaikwad Last revision by Bentley Colleague Tanaji Gaikwad
    • When: Thu, Aug 3 2023 1:43 AM
    • Revisions: 3
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies