N2125-12: No unused section identifiers found... Note message appeared while using AutoPIPE, why?


Applies To
Product(s):AutoPIPE
Version(s):2004, XM, V8i, CONNECT;
Area: Note Message
Original Author:Bentley Technical Support Group
Date Logged
& Current Version
Feb. 2016
10.00.00.10

Problem:

The following appeared while using AutoPIPE:

Coincident Node Check (Analysis > Model Validation > Coincident Node Check)

---------------------------
Note
---------------------------
N2125-12: No unused section identifiers found
---------------------------
OK
---------------------------

Why?

Solution:

Typically this note message will appear when trying to delete Unused Section Identifiers, and no unused section Identifiers have been found in the model. Either there are no beams in the model or all section Identifiers added are being used by existing modeled beams.

Open the model's input grids; a. Section Id tab and then b. Beam tab. The beam tab will detail all of the beams that have been added into the model. Each Beam component must be configured with a specific Section Id. That Beam Section ID must be listed on the list of Section ID tab. If not, add a new Section ID and reconfigure Beam components as needed to have the proper Section ID.

Again, the message will appear if any of the following are met when pressing the Delete> Unused Section Identifier button:

1. There are no user defined Section Ids added to the model. Only default Section ID = 0 remains on the Section ID tab.

2. All of the Section Ids listed on the Section Id tab are being used somewhere in the model. 

Note: The default Section Id, 0, cannot be deleted from the model. 

See Also

"Note" Messages in AutoPIPE

Bentley AutoPIPE