Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
AutoPIPE
  • Product Communities
AutoPIPE
AutoPIPE Wiki 15. Can we use material which has allowable stress values in code but yield strength and tensile strength values are not available?
    • Sign In
    • -Pipe and Vessel Stress Analysis - Wiki
      • +.Bentley AutoPIPE
      • -.Bentley AutoPIPE Vessel (powered by Microprotol)
        • +Features and Bugs
        • +General Information
        • -Support Solutions and FAQ's
          • +Air Coolers
          • Boilers
          • +Calculations
          • +Coils
          • +Cost Estimation
          • +Drawings
          • +Expansion Joints
          • +Import / Export
          • +Interface
          • +Lifting Lugs
          • +Loads and Load Combinations
          • -Material, Material Database, and Default Libraries
            • 01. "Not a valid Material Database load it manually" message appears when using AutoPIPE Vessel, why and how to avoid?
            • 02. How are nominal design stresses calculates in AutoPIPE for a material?
            • +03. How to add a new material into AutoPIPE Vessel
            • 04. How to create a small material database for a few select list of materials and merge it to another database?
            • 05. How to delete an existing material from the database?
            • 06. How to Input user defined material factor of safety for changing design allowable stress as per various codes in AutoPIPE Vessel?
            • 07. How to make modification to existing standard flange material ?
            • 08. What resources does fixed heat exchangers use for EN 13445 thermal expansion coefficient?
            • 09. Why is the does a model have this Impact Test error message being displayed in AutoPIPE Vessel?
            • 10. On selecting a shell component and in the materials tab when clicking on OK, the length becomes 0. How do I resolve this?
            • 11. Why does not the materials window> design tab show the properties for the actual computed thickness in AutoPIPE Vessel?
            • 12. How does AutoPIPE Vessel handle entry in the "Clad / Overlay Thk" field?
            • 13. Why component Material selection does not populate properties for ambient or design fields in AutoPIPE Vessel?
            • 14. Software is crashing while changing the material using multiple selection of elements.
            • 15. Can we use material which has allowable stress values in code but yield strength and tensile strength values are not available?
            • 16. When printing data for a material, young's modulus values printed are not same as input values, Why?
          • +Nozzles and Flanges
          • +Pressure Vessels
          • +Report
          • +Shell and Tube Heat Exchangers
          • +Shells
          • +Soil
          • +Tanks
          • +Units
          • +Vortex Shedding
          • +Weld Joints
        • +System Messages
        • +Video Gallery
      • +ADL PIPE
      • +Bentley AutoPIPE Nozzle
      • +Bentley PlantFLOW
      • +Bentley PULS
    • +AutoPIPE Brand Learning Resources
    • +Attend a live meeting with an AutoPIPE Analyst

     
     Questions about this article, topic, or product? Click here. 

    15. Can we use material which has allowable stress values in code but yield strength and tensile strength values are not available?

    Applies To
    Product(s): AutoPIPE Vessel
    Version(s): ALL
    Area: modeling
    Date Logged
    & Current Version
    May 2023
    43.01.01.011

    Problem:

    Can we use material which has allowable stress values in code but yield strength and tensile strength values are not available?

    Solution:

    As per ASME Section II Part D, few material has allowable stress values present at specific temperature but there are no yield strength and tensile strength values are available for the same material at same temperature. 
    For Example SA387 Gr22 Cl2 at temperature 5500C, We have the allowable stress values but there are no values for yield strength and tensile strength available in code.
    As these values are not available in code we suggest following option,
    1. Use another material (We don't encourage the option 2 & 3, User has to decide their own)
    2. If you know the values you can edit as shown below
    3. You can add new material if you have the more details about the material which is not available in code, to know how to add click here

    See Also

    Material, Material Database, and Default Libraries

    AutoPIPE Vessel

    • AutoPIPE Vessel
    • material
    • Share
    • History
    • More
    • Cancel
    • Tanaji Gaikwad Created by Bentley Colleague Tanaji Gaikwad
    • When: Tue, Jun 20 2023 3:58 AM
    • Tanaji Gaikwad Last revision by Bentley Colleague Tanaji Gaikwad
    • When: Tue, Jun 20 2023 7:51 AM
    • Revisions: 2
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies