<?xml version="1.0" encoding="UTF-8" ?>
<?xml-stylesheet type="text/xsl" href="https://communities.bentley.com/cfs-file/__key/system/syndication/rss.xsl" media="screen"?><rss version="2.0" xmlns:dc="http://purl.org/dc/elements/1.1/"><channel><title>02-03.d: Aveva E3D PSI (XML) into AutoPIPE import issues</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/68549/02-03-d-aveva-e3d-psi-xml-into-autopipe-import-issues</link><description /><dc:language>en-US</dc:language><generator>Telligent Community 12</generator><item><title>02-03.d: Aveva E3D PSI (XML) into AutoPIPE import issues</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/68549/02-03-d-aveva-e3d-psi-xml-into-autopipe-import-issues</link><pubDate>Mon, 11 Sep 2023 15:13:06 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:8ce9b506-3b75-425b-8f9e-279799eadc9c</guid><dc:creator>Mike Dattilio</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/68549/02-03-d-aveva-e3d-psi-xml-into-autopipe-import-issues#comments</comments><description>Current Revision posted to AutoPIPE Wiki by Mike Dattilio on 9/11/2023 3:13:06 PM&lt;br /&gt;
&lt;table style="background-color:#000080;"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;&lt;span style="color:#ffffff;"&gt;&lt;strong&gt;&lt;span style="font-size:150%;"&gt;Import Process&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;While using Aveva E3D PSI, export a XML file (reference Aveva Help for details on exporting this file). Next open AutoPIPE and select E3D PSI(*.xml) import command (File &amp;gt; Import/Export &amp;gt; Import &amp;gt; E3D PSI(*.xml)). The application will display an Open dialog, search for the XML file to be opened, press Open button, process through any any additional dialogs as needed, and in a moment the model should be displayed in AutoPIPE.&amp;nbsp;&lt;/p&gt;
&lt;table style="background-color:#000080;"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;&lt;span style="color:#ffffff;"&gt;&lt;strong&gt;&lt;span style="font-size:150%;"&gt;Known E3D PSI Import Issues&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p style="padding-left:30px;"&gt;&lt;strong&gt;01. Model cannot be imported:&lt;/strong&gt;&lt;/p&gt;
&lt;p style="padding-left:90px;"&gt;There can be any number of reasons why a model cannot be imported. Here is a list of known issues&lt;/p&gt;
&lt;p style="padding-left:120px;"&gt;&lt;span style="text-decoration:underline;"&gt;i. Bad file from E3D&lt;/span&gt;&lt;/p&gt;
&lt;p style="padding-left:150px;"&gt;As of September 2023 an E3D PSI file was sent with the following problems. (open the XML file in any word editor and review).&amp;nbsp;&lt;/p&gt;
&lt;p style="padding-left:150px;"&gt;Suggest to contact E3D PSI technical support to address issues with creating a bad exported XML file.&amp;nbsp;&lt;/p&gt;
&lt;p style="padding-left:150px;"&gt;1. &amp;lt;Temperature1&amp;gt;-100000&amp;lt;/Temperature1&amp;gt;&lt;/p&gt;
&lt;p style="padding-left:150px;"&gt;&amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; Comment:&amp;nbsp;no temperature should be set to this value&lt;/p&gt;
&lt;p style="padding-left:150px;"&gt;2. &amp;lt;NodeNumber&amp;gt;-1&amp;lt;/NodeNumber&amp;gt;&lt;/p&gt;
&lt;p style="padding-left:150px;"&gt;&amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; Comment: Node numbers cannot have a -ve value.&lt;/p&gt;
&lt;p style="padding-left:150px;"&gt;3. &amp;lt;ComponentType&amp;gt;BRAN&amp;lt;/ComponentType&amp;gt;&lt;/p&gt;
&lt;p style="padding-left:150px;"&gt;&amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; Comment: AutoPIPE does not have a BRAN component and thus the component cannot be imported&lt;/p&gt;
&lt;p style="padding-left:150px;"&gt;4. &amp;lt;OutsideDiameter&amp;gt;2.36220472440945&amp;lt;/OutsideDiameter&amp;gt;&lt;/p&gt;
&lt;p style="padding-left:150px;"&gt;&amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; Comment: no standard pipe size with this exact size&lt;/p&gt;
&lt;p style="padding-left:150px;"&gt;5. &amp;lt;WallThickness&amp;gt;0&amp;lt;/WallThickness&amp;gt;&lt;/p&gt;
&lt;p style="padding-left:150px;"&gt;&amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; Comment: this is an error that must be fixed before importing.&lt;/p&gt;
&lt;p style="padding-left:30px;"&gt;02.&amp;nbsp;&lt;/p&gt;
&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: E3D, import, PSI, AutoPIPE, XML&lt;/div&gt;
</description></item><item><title>02-03.d: Aveva E3D PSI (XML) into AutoPIPE import issues</title><link>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/68549/02-03-d-aveva-e3d-psi-xml-into-autopipe-import-issues/revision/1</link><pubDate>Mon, 11 Sep 2023 15:03:36 GMT</pubDate><guid isPermaLink="false">6dad98f5-dbc9-4c4d-a9ba-e9da8dc6aa8e:8ce9b506-3b75-425b-8f9e-279799eadc9c</guid><dc:creator>Mike Dattilio</dc:creator><comments>https://communities.bentley.com/products/pipe_stress_analysis/w/pipe_stress_analysis__wiki/68549/02-03-d-aveva-e3d-psi-xml-into-autopipe-import-issues#comments</comments><description>Revision 1 posted to AutoPIPE Wiki by Mike Dattilio on 9/11/2023 3:03:36 PM&lt;br /&gt;
&lt;table style="background-color:#000080;"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;&lt;span style="color:#ffffff;"&gt;&lt;strong&gt;&lt;span style="font-size:150%;"&gt;Import Process&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p&gt;While using Aveva E3D PSI, export a XML file (reference Aveva Help for details on exporting this file). Next open AutoPIPE and select E3D PSI(*.xml) import command (File &amp;gt; Import/Export &amp;gt; Import &amp;gt; E3D PSI(*.xml)). The application will display an Open dialog, search for the XML file to be opened, press Open button, process through any any additional dialogs as needed, and in a moment the model should be displayed in AutoPIPE.&amp;nbsp;&lt;/p&gt;
&lt;table style="background-color:#000080;"&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td&gt;&lt;span style="color:#ffffff;"&gt;&lt;strong&gt;&lt;span style="font-size:150%;"&gt;Known E3D PSI Import Issues&lt;/span&gt;&lt;/strong&gt;&lt;/span&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p style="padding-left:30px;"&gt;01. Model cannot be imported:&lt;/p&gt;
&lt;p style="padding-left:90px;"&gt;There can be any number of reasons why a model cannot be imported. Here is a list of known issues&lt;/p&gt;
&lt;p style="padding-left:120px;"&gt;i. Bad file from E3D&lt;/p&gt;
&lt;p style="padding-left:150px;"&gt;As of September 2023 an E3D PSI file was sent with the following problems. (open the XML file in any word editor and review).&amp;nbsp;&lt;/p&gt;
&lt;p style="padding-left:150px;"&gt;1. &amp;lt;Temperature1&amp;gt;-100000&amp;lt;/Temperature1&amp;gt;&lt;/p&gt;
&lt;p style="padding-left:150px;"&gt;&amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; Comment:&amp;nbsp;no temperature should be set to this value&lt;/p&gt;
&lt;p style="padding-left:150px;"&gt;2. &amp;lt;NodeNumber&amp;gt;-1&amp;lt;/NodeNumber&amp;gt;&lt;/p&gt;
&lt;p style="padding-left:150px;"&gt;&amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; Comment: Node numbers cannot have a -ve value.&lt;/p&gt;
&lt;p style="padding-left:150px;"&gt;3. &amp;lt;ComponentType&amp;gt;BRAN&amp;lt;/ComponentType&amp;gt;&lt;/p&gt;
&lt;p style="padding-left:150px;"&gt;&amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; Comment: AutoPIPE does not have a BRAN component and thus the component cannot be imported&lt;/p&gt;
&lt;p style="padding-left:150px;"&gt;4. &amp;lt;OutsideDiameter&amp;gt;2.36220472440945&amp;lt;/OutsideDiameter&amp;gt;&lt;/p&gt;
&lt;p style="padding-left:150px;"&gt;&amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; Comment: no standard pipe size with this exact size&lt;/p&gt;
&lt;p style="padding-left:150px;"&gt;5. &amp;lt;WallThickness&amp;gt;0&amp;lt;/WallThickness&amp;gt;&lt;/p&gt;
&lt;p style="padding-left:150px;"&gt;&amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; &amp;nbsp; Comment: this is an error that must be fixed before importing.&lt;/p&gt;
&lt;p style="padding-left:30px;"&gt;02.&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;/p&gt;
&lt;div style="clear:both;"&gt;&lt;/div&gt;

&lt;div style="font-size: 90%;"&gt;Tags: E3D, import, PSI, AutoPIPE, XML&lt;/div&gt;