11. How to fix when some pipe element is extracted in the summary sheet in Rev -section in Stress Is


Applies To
Product(s):AutoPIPE
Version(s):ALL
Area:Isometric
Original Author:Bentley Technical Support Group
Date Logged
& Current Version
Oct. 2023
23.00.00.23

Problem:

How to fix when some pipe element is extracted in the summary sheet in Rev -section in Stress Isometric?

Solution:

In this case the window extends of the Report Seed file have been shifted.
In order to solve this issue, follow the following steps given below:

  1. Select the Segment or the range for isometric extraction.
  2. Go to File > Save Stress Isometric > Select the folder in which ISO will extract > Autopipe Isometric Manager options > Settings > Copy the Drawing Frame file address. As shown screenshot below.

  3. Now go to file address you have copied. For e.g.:   "c:\programdata\bentley\autopipe 2023\isoextractor\borders\dwg". As shown in the screenshot below 

    This file location depends on which format you are extracting the isometric or in which format you want to make the changes either .dwg or .dgn. As you can see the screens shot below.
      

  4. Now as per the sheet size you have to select the Report seed file. For E.g. In my case the sheet size is ANSI "E" paper size (34" x 44"). So, I have selected "EREPORT" as shown screenshot above.

  5. Open the EREPORT file in OPIM and select Open the File with NO Workset. As shown screenshot below.

  6. Then Go to Tools > Window Extent > Change. As shown in screenshot below.

           

       7. Set the window extent somewhere outside the layout. As shown in screenshot below.

          

     8. Close Set the isometric window area and save settings for the Report Seed file.

     9. Extract the stress isometric again.

Note: Suggested not to make any change in the default settings of the Seed Files until and unless very much required.