Digits of decimals for length column in Point Connectivity section is not aligned with value given in Edit Model Option, Why?
Input:
Output:
Software is working as designed and user can change the decimal places for length column as per there requirement.
Follow the steps given below,
Step 1: Enter the required digits after decimal points in Edit model option,
Step 2: Open the report template file (PointConnectivityDataTemplate.xml) from path: C:\Program Files (x86)\Bentley\AutoPIPE 2023\ReportTemplates\Text
Step 3: Open the PonitConnectivityDataTemplate.xml file in any text editor (like Notepad++) and go to the Length section,
Step 4: Copy the line number 104 (Marked in Red) and replace line number 80 and 92 with line number 104 as shown in above image. Save the file and run the analysis and you will get the required digits after decimal points in point connectivity report.