Applies To | |
Product(s): | AutoPIPE Vessel |
Version(s): | ALL |
Area: | General |
Date Logged & Current Version | Jan 2024 44.00.01.014 |
Allowable longitudinal compressive Stress (σ c,all) is not calculated as per EN13445-3 Clause 16.14-29, Why?
Instead design stress value is taken as allowable longitudinal compressive stress. Please clarify.
Allowable longitudinal compressive stress value shown in report is correct.
Refer clause 16.14.8, this clause clearly says if equation 16.14-15 satisfied then design stress can be taken as allowable longitudinal compressive stress.
In this case (Operating Corroded condition),
Mean Diameter (D) : 855.4 mm
Thickness (ea) : 34.7 mm
Modulus of elasticity (E) : 189000 MPa
Sigma e : 105.6 MPa
D/ea (24.65) ≤ 0.06 * E / Sigma e (107.38)
As equation 16.14-15 satisfied design stress value (126.7 MPa) is taken as allowable longitudinal compressive stress.