When revieing the output report of a particular model analyzed per BS PD 5500, the following was observed.
1. In the "Summary of Errors and Warnings" subsection of the report:
417 NOZZLE 10: Insufficient reinforcement.
2. Under the Isolated opening subsection for Opening 10, the following was mentioned:
No reinforcement is required (see paragraph 3.5.4.3.3, note 1)
These messages are in direct conflict. Which is correct?
The cited note from 3.5.4.3.3, note 1):
According to the report:
So the value of erb/ers should be very high, but also unknown as it is out of scope. In the report we have:
Which is false.. A new bug (1360474) has been logged and will be added to a future version of the program.
Warning Messages, Unregistered Messages, Error Messages, or Application Crash issues