AutoPIPE Preview Handler error on installation
Closed loop detected in imported model at TEE point XXX.
E13-16: Cannot Find the specified units file
E13-63: Invalid code material(s) detected.
E15-13: PXD file is needed for accessing AutoPLANT data in this model Please place PXD and PXH files in same directory as DAT file.
E15-34: Select Material library does not match
E21-40: Executing this operation can corrupt distributed load records in AutoPIPE
E31-37: Material type not recognized. Re-enter
E36-42: Tie/Link must be connected to another point
E36-43: Connected point cannot be the current point
E36-70: Cost must be greater than zero
E38-95: Cannot insert component after a tee
E39-27: Zero length not permitted
E40-100: ASME B31J requires angle to be greater than 5.0 deg and less than 60 deg
E54-79: No Joint Type & User SIF at the selected location(s)
E90-21: Analysis results do not exist
E90-43: Structural Synchronizer not installed on the system.
E102-155: This point must be an anchor/reference point
E102-161: This point does not have reference point defined
E119-1: Maximum number of load combinations exeeded
E131-30: AUTOPIPE.CLR not found
E154-16: This value must be between 0 and 2, recommended value is 0.5
E156-38: Value must be greater than zero
E175-28: Error in velocity profile specification
E221: Please contact Rebis
E511-1: Invalid AutoPIPE data file
E512-65: the model cannot be opened
E512-109 cannot open Projectwise model
E512-149: Model name must not contain space character before extension
E514-2: Unable to retrieve Time History Load and Time History files
E516-8: Demo version limit of 20 points exceeded
E516-11: Analysis terminated: model must have more than one point
E521-22: Base point is not on selected range
E521-24: No range specified for copying
E522-32: Cannot find clipboard file in current directory
E522-33: Cannot complete the paste operation
E523-21: No Range specified for rotation
E527-25: Point not found in selected range
E723-23: System is not complete for analysis purposes
E726-104: Zero length not allowed at beam XX
E732-1: Angle is 0 deg. at bend xxx
E732-2: Angle is 180 deg. at bend xxx
E732-3: Not enough clearance to fit bend xxx
E737-26: Valve components are not permitted in HDPE pipe system as per CC N-755-1
E751-1 Tee type gt 8 or lt 1. SIF not calculated
E753-18 Cannot be reducer face
E774-44: Equation requires more combinations to be complete
E801-1: FATAL ERROR: Unstable System
E801-3: No static load cases specified
E801-4: Zero length element
E801-5: Zero Element Stiffness in AutoPIPE
E801-6: Zero flexible length beam
E801-11: Fatal Error: no mass in the system
E801-12: Cannot find next frequency
E801-24: Number of MSRS groups is inconsistent with SAM case - Error Message in AutoPIPE
E801-62: Unable to process any time history function
E801-64: Undefined point name in time history load data
E801-75: Cannot allocate memory for analysis, unload some applications.
E801-77: Multiple use of same THP file name at a point. May copy and rename
E801-135: Number of analysis nodes exceeds maximum limit of 10000 nodes
E829-1: Incorrect model size in file Static analysis results will be ignored.
E951-1: No default available. Re-enter
E951-3: Expecting real input. Re-enter
Answer: insert a valid value into the current field before selecting a different cell / OK button. Example: Spaces at the end of "Line class", in PIPE ID properties.
E951-31: Cannot find or read autoplan.cnf file. Please reinstall the program.
Only solutions; a. copy CNF from coworker to install folder or, reinstall the application.
E962-1: File read error, please contact BENTLEY
E962-2: File write error, check disk space
E963-8: Non-ascii characters or "?" are not permitted in name
E963-21: Number of characters in name cannot exceed 48
E2164-15: Qualified stress for all bend and tee components should be greater than zero
Error 1316 - A network error occurred while attempting to read from the file
LoadLibrary failed with error 87
LoadLibrary failed with error 1114: A dynamic link library (DLL) initialization routine failed
No load case is selected to print time history results
No Piping with OD >= 1.400 inches is found in PXF file
Program failed to generate C2 file
"Root Element Is Missing"
The model you are about to open as last modified in a newer version...
Time history analysis file (*.TIM) does not exist.
Warnings, Errors, Crashed, Confirm Messages