W21-21: Cannot perform this operation, multiple points selected
W21-32: Cannot split segments, maximum number of segments reached
W21-34: This function can only be applied on junction of two segments
W21-38: This function cannot be applied at the current point.
W31-86: No allowable stresses are available for the selected material in the material library
W36-14: Support will be hidden since all gaps > Gap Scale Factor x Pipe O.D.
W41-27: Parameters are outside the applicable range
W72-1: AutoPIPE Error Handling
W79-85: 0 Stiffness in direction of imposed harmonic load. at XXX
W97-99: No analyzed pressure cases present. Only axial GR stress is added
W97-213: Corroded thickness is required for sustained stress in B31.3
W177-22: Time history duration is less than first period
W214-1: The combination data file (*.CMB) you are about to open was created in a different version.
W507-14: Modal analysis cannot be performed. Number of modes is zero
W507-40: No temperature case found for non-linear hydrotest.
W507-43: No pressure case found for non-linear hydrotest
W511-67: Hydrotest load cases have been removed from existing analysis sets and new hydrotest loadset has been added.
W726-2: Gap orientation has changed for guide at point XXX
W726-6: Near zero length element at point XXX
W726-7: Pipe diameter change without a reducer at point XXX
W726-8: Kink in straight run of 90.0 deg at point XXX
W726-8: Kink in straight run of 179.9 deg at point XXX
W726-9: A Guide or Line Stop should not be inserted at following kink point(s)
W726-10: User SIF required at junction at following point(s)
W726-12: Following Segment(s) not connected to other segments and has no anchors
W726-14: No anchors in current system
W726-34: Inconsistent coordinates were reset at following point(s)
W726-37: Expansion at (load case) is outside of temperature range at point XXX for material YYYY
W726-38: Allowable at ambient is outside of temperature range at point XXX for material YYYY
W726-39: Allowable at XX is outside of temperature range at point XXX for material XXXX
W726-55: Creep data for (xx) is above temperature range. Zero allowable used at point (xxx) for material (yyyy)
W726-93: Zero weight flange found at point XXX
W726-94: Zero weight valve found at point XXX
W726-110: Not all gaps are non-zero for following support(s)
W726-116: Support will be hidden since all gaps > gap scale factor*Pipe O.D.at following support
W726-170: The tee at point A04 has only two legs defined which may not meet the conditions to apply the equations for SIF and other stress indices.
W726-195: Support D10 1-Zero length from 'supported' to 'connected' point
W726-205: SIF and flexibility factors have not been validated for D/t > 100
W727-2: Temperature is outside the range specified the code for Expansion
W727-3: Temperature is outside the range specified by the code for allowable
W754-1: Sweep angle is 180 degrees
W774-47 One or more combinations are set to none
W801-14: No frequency below cutoff value
W801-58: Smallest timestep for xxxx .TIH file = ....
W801-121: V-stop liftoff(s) have occurred under operating
W831-11: Seismic level includes cases not analyzed
W961-12: System near capacity, please save
W2014-35: Previous "to" must be the same as current "from" point
W2018-11, W2018-12, W2018-16: Not authorized for ???? edition, AutoPIPE reverts to DEMO mode
W2143-1 Following inconsistent data found in Analysis Set 1 Number of load cases does not match
W2143-7: The joint information of User SIF or flange will be ignored at following point(s)
W2143-29:Response spectrum case R1 has support group 2 that is no longer defined in model
W2143-37: Extremely high value for Displacement tolerance > 1000 detected in loadset
W2143-41: Undefined case referenced for concentrated force found at point..
W2143-45: A Yield(Sy) value of less than or equal to 1.00000 psi is detected on some points
W2143-76: Friction scale factor is zero. Friction at all supports will be ignored for following analysis set
W2143-108: Stress Range factor > 1 is not allowed for non-ferrous materials. At Pipe(s)
W2143-121: Sc > 20 ksi (138 MPa). In calculation Sc will be set to 20 ksi (138 MPa) for expansion allow for pipe(s)
W2143-123: Sh > 20 ksi (138 MPa). In calculation Sh will be set to 20 ksi (138 MPa) for expansion allow at following point(s)
W2164-12: System contains Gaps/Friction/Soil data. Please enable non-linear option in the following Analysis sets
W2164-30: Outside diameter does not match with soil properties at following point(s)
W2164-58: Soil ID: xxx ,Bedding const. K cannot be zero. Reset to 0.1
W2164-78: D/t ratio for the following pipe ID(s) is less than 20
W2164-93: The value of "Fluid Density Factor" is zero in following analysis sets
W2164-94: The validity of SIF data is only demonstrated for a Do/tn ratio less than or equal to 100
W2164-104: Yield values are zero for the selected material
W2164-106: The following pipe ID's are using a depreciated fatigue curve, limited to 1E6 cycles
W2164-124: B31 App J: Stress intensification factors
W2164-125:B31 App J: Crotch radius is less than or equal to zero for the tee(s)
W2164-126:B31 App J: Crotch thickness is less than or equal to zero for the tee(s)
W2164-135:B31 App J: The ratio of crotch thickness to run thickness must be greater than 1.1 for the tee(s)
W2164-145:B31 App J: SIF values for the tee(s) below are not valid
W2164-147:B31 App J: SIF values for the tee(s) below are not valid, as the ratio of branch mean diameter to run mean diameter is greater than 0.6
W2164-153: B31 App J - The ratio r2/D2 is smaller than or equal to 0.08 for the reducer(s)
W2164-155: B31 App J - The ratio T1/T2 is smaller than or equal to 1.00 for the reducer(s)… warning message occurred in AutoPIPE, why?
W2164-156: B31 App J - The ratio T1/T2 is greater than or equal to 2.12 for the reducer(s)… warning message occurred in AutoPIPE, why?
W2164-159: The value of "Stiffness" or "Spring Rate" is zero
W2164-173:Thickness is out of range of library limits for following pipes
W2164-178:Tee header and branch data was corrupt ...
W2164-181: B31 App J: The following tee(s) contain a primary or secondary node on the branch leg
W2164-192:B31 App J: Collinearity detected on the following tee(s) and will be analyzed as a non-B31J component
W2164-194:B31 App J: The branch pipe axis is not within 5 degrees normal to the axis of the run pipe for the following tees
W2164-198:Tee header and branch missing information has been updated on the following point(s):
W2164-204: The following flange(s) do not consider corrosion
W2182-4: Valve/reducer/flex joint should have flanges at both ends
W2182-26: Pressure rating on mating flange to a valve is not the same at point xxxx
W2261-3: Invalid Pipe ID in "Virtual Anchor" data for following Soil Id(s)
W2261-4: Invalid Point in "Virtual Anchor" data for following Soil Id(s)
W2261-5: The load case selected in "Virtual Anchor" data for following Soil Id(s), does not exist in model
W2261-9: All stiffness values are zero for the following bilinear support(s).