W21-38: This function cannot be applied at the current point.
W31-86: No allowable stresses are available for the selected material in the material library
W41-27: Parameters are outside the applicable range
W72-1 AutoPIPE Error Handeling
W79-85: 0 Stiffness in direction of imposed harmonic load. at XXX
W97-99: No analyzed pressure cases present. Only axial GR stress is added
W97-213: Corroded thickness is required for sustained stress in B31.3
W177-22: Time history duration is less than first period
W214-1: The combination data file (*.CMB) you are about to open was created in a different version.
W507-14: Modal analysis cannot be performed. Number of modes is zero
W507-40: No temperature case found for non-linear hydrotest.
W507-43: No pressure case found for non-linear hydrotest
W511-67: Hydrotest load cases have been removed from existing analysis sets and new hydrotest loadset has been added.
W726-2: Gap orientation has changed for guide at point XXX
W726-6: Near zero length element at point XXX
W726-7: Pipe diameter change without a reducer at point XXX
W726-8: Kink in straight run of 90.0 deg at point XXX
W726-8: Kink in straight run of 179.9 deg at point XXX
W726-12: Following Segment(s) not connected to other segments and has no anchors
W726-14: No anchors in current system
W726-34: Inconsistent coordinates were reset at following point(s)
W726-38: Allowable at ambient is outside of temperature range at point XXX for material YYYY
W726-39: Allowable at XX is outside of temperature range at point XXX for material XXXX
W726-55: Creep data for (xx) is above temperature range. Zero allowable used at point (xxx) for material (yyyy)
W726-93: Zero weight flange found at point XXX
W726-94: Zero weight valve found at point XXX
W726-110: Not all gaps are non-zero for following support(s)
W726-170:The tee at point A04 has only two legs defined which may not meet the conditions to apply the equations for SIF and other stress indices.
W726-195:Support D10 1-Zero length from 'supported' to 'connected' point
W727-2: Temperature is outside the range specified the code for Expansion
W754-1: Sweep angle is 180 degrees
W801-14: No frequency below cutoff value
W801-58: Smallest timestep for xxxx .TIH file = ....
W831-11: Seismic level includes cases not analyzed
W961-12: System near capacity, please save
W2014-35: Previous "to" must be the same as current "from" point
W2018-11, W2018-12, W2018-16: Not authorized for ???? edition, AutoPIPE reverts to DEMO mode
W2143-7: The joint information of User SIF or flange will be ignored at following point(s)
W2143-37:Extremely high value for Displacement tolerance > 1000 detected in loadset
W2143-45: A Yield(Sy) value of less than or equal to 1.00000 psi is detected on some points
W2143-76:Friction scale factor is zero. Friction at all supports will be ignored for following analysis set
W2143-108: Stress Range factor > 1 is not allowed for non-ferrous materials. At Pipe(s)
W2143-121 Sc > 20 ksi (138 MPa). In calculation Sc will be set to 20 ksi (138 MPa) for expansion allow for pipe(s)
W2143-123 Sh > 20 ksi (138 MPa). In calculation Sh will be set to 20 ksi (138 MPa) for expansion allow at following point(s)
W2164-12:System contains Gaps/Friction/Soil data. Please enable non-linear option in the following Analysis sets
W2164-30: Outside diameter does not match with soil properties at following point(s)
W2164-93: The value of "Fluid Density Factor" is zero in following analysis sets
W2164-104:Yield values are zero for the selected material
W2164-106:The following pipe ID's are using a depreciated fatigue curve, limited to 1E6 cycles
W2182-4: Valve/reducer/flex joint should have flanges at both ends
W2182-26: Pressure rating on mating flange to a valve is not the same at point xxxx