Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
AutoPIPE
  • Product Communities
AutoPIPE
AutoPIPE Wiki 01. PCF Translator FAQ & troubleshooting - AutoPIPE
    • Sign In
    • -Pipe and Vessel Stress Analysis - Wiki
      • +ADL PIPE
      • -Bentley AutoPIPE
        • +- General Information about AutoPIPE
        • +- NEW User Guide for AutoPIPE
        • +- Technical Support - AutoPIPE
        • +Batch Processing, ITS, and ATS using AutoPIPE
        • AutoPIPE QA&R program
        • +Download - Install - Release Notes - AutoPIPE
        • +File / Model Management using AutoPIPE
        • +General - AutoPIPE
        • +Graphics - AutoPIPE
        • +Grids (Input & Results) - AutoPIPE
        • -Import and Export - AutoPIPE
          • 01: What file formats can AutoPIPE Import/Export?
          • -02. Imported related issues in AutoPIPE
            • +02-01.a: Import AutoPIPE DAT model
            • +02-01.b: Issues with Importing *.NTL file into AutoPIPE
            • -02-02. AutoPIPE Translators
              • +ADLPipe Translator - AutoPIPE
              • -PCF Translator Issues for AutoPIPE
                • -01. PCF Translator FAQ & troubleshooting - AutoPIPE
                  • 0. How to install AutoPIPE's PCF translator?
                  • +01. PCF Import process aborted or crashed: what should I do?
                  • +02. PCF Translator Freezes / Not Responding / disappears from screen; now what should I do in AutoPIPE?
                  • 03. Import from Autodesk Inventor PCF files show flanges and valves as weightless “Zero Weight” components, why and how to avoid when using PCF translator in AutoPIPE?
                  • 04. "E880-1: Error in opening import batch file. File extension must be NTL" message appear when importing a PCF fiule in AutoPIPE, why and how to avoid?
                  • 05. No graphical elements found for the components after importing file into AutoPIPE
                  • 06. Branch piping is not connected to the main header pipe in converted AutoPIPE PCF file, why?
                  • 07. When importing a PCF file, all the pipe sizes are very large or small in AutoPIPE, why and how to resolve?
                  • 08. When I open the .NTL file in AutoPIPE, it truncates my pressure values, why and how to avoid?
                  • +09. Is my piping code, material, and component supported in AutoPIPE's PCF translator?
                  • 10. Imported PCF file containing branch connection O-let / olet (weldolet, elbolet, threadolet, etc..) are not connected correctly in AutoPIPE model, why and how to avoid?
                  • 11. When importing a PCf file into AutoPIPE, Status = "Incorrect Component Connection Tolerance Value", why and how to avoid?
                  • 12. When importing a PCF file, all the pipe wall thickness values are very large in AutoPIPE, why and how to resolve?
                  • 13. How to map a Line Number from a PCF file into AutoPIPE?
                  • 13. PCF Translator closes abruptly when importing a model into AutoPIPE, how to fix it?
                  • +14. Mapping examples from PCF translator to AutoPIPE?
                  • 15. Why are parts of my PCF translated file into AutoPIPE missing piping or components?
                  • 16. Why are all imported flanges from a PCF file rotated 90 deg when opened in an AutoPIPE model?
                  • 17. How to reset the PCF translator PCFin.MAP used inside of AutoPIPE?
                  • 18. Parts of my PCF translated file into AutoPIPE have piping that is not connected, why?
                  • 19. How to remove Cad Length from AutoPIPE Model?
                  • 20. Cannot select a specific item from drop down listing when importing a PCF file into AutoPIPE, why?
                  • 21. How to filter out small bore piping from being translated into an AutoPIPE model?
                  • 22. What units are used for and how is the Bend Radius calculated when importing a PCF file into AutoPIPE?
                  • 23. How are bend radius calculated when importing a PCF file into AutoPIPE?
                  • 24. PCF Imported Bends are shown as straight pipe in AutoPIPE, why/
                  • Q. How to create a PCF file for AutoPIPE?
                • 03. PCF Translator: Known Issues
                • +04. PCF Translator Version History
                • +05. Added details about AutoPIPE's PCF Translator "Tools > Settings"
                • Q. Documentation on AutoPIPE's PCF translator
              • +STRAIT Translator in AutoPIPE
            • +02-02.d Import ISM files into AutoPIPE
            • 02-03.a1: Example 1 - After import, how to fix piping that are not all connected?
            • 02-03.a2: Example 2 - After import, how to fix piping that are not all connected?
            • +02-03.b: Import MS Excel or AutoCAD DWG / DXF into AutoPIPE?
            • 02-03.c: AutoDesk REVIT into AutoPIPE
            • 02-03.e.i: PXF Import : CADAP.MAP Options
            • +02-03.e: Troubleshooting - Import AutoPlant / OpenPLANT PXF file into AutoPIPE
            • 02-03.f: Can AutoPIPE Import Bentley Microstation model information?
            • 02-03.f: Can AutoPIPE V8i Import / Export Bentley HAMMER loads?
            • +02-03.h: Import PlantSPACE model into AutoPIPE
            • 02-03.i: Import ProStructures into AutoPIPE
            • +02-03.j: Insert> Model From Bentley SACS using PipeLink or ISM
            • +02-03.k: Insert> Model From STAAD Using PipeLink
            • 02-03.l: CAD To AutoPIPE Integration
            • 02-03.m: Import CIMSteel Integration Standards (CIS/2) or STP file information into AutoPIPE
            • +02-03.n: Import / Export caesar (cii) or Areva PDMS (cii) with AutoPIPE
            • 02-03.o: Import CAE Pipe or Kpipe into AutoPIPE
            • 02-03.r: Import OpenBIM data exchange (IFC) information into AutoPIPE
            • 02-03.s: Import Pipe Net into AutoPIPE
            • 02-03.t: Import PDMS using I-Sketch, I-Run or Spoolgen into AutoPIPE
            • 02-03.u: Import PTC Creo into AutoPIPE
            • 02-03.v: Can AutoPIPE Import SAP 2000 model file?
            • 02-03.w: Import TRIMBLE PIPEDESIGNER 3D into AutoPIPE
            • 04-001: While importing or copy paste into AutoPIPE model, the node numbers are renaming automatically. How to import / copy geometry without changing the node numbers?
          • +03. Exported related issues in AutoPIPE
        • +Known Issues in AutoPIPE (Enhancements, defects, etc..)
        • +Libraries - AutoPIPE
        • +License AutoPIPE -
        • +Loads and Load Sets - AutoPIPE
        • +Localization (Non-English Language) - AutoPIPE
        • +Modeling Approaches in AutoPIPE
        • +Modules (i.e. Flange Analysis, Spring Hanger Selection, Rotating Equip, TTA) in AutoPIPE
        • +Piping codes - AutoPIPE
        • +Post Processing - AutoPIPE
        • +Printing - AutoPIPE
        • +Reports - AutoPIPE
        • Security
        • +Settings - AutoPIPE
        • +Stress Isometrics - AutoPIPE
        • +Technology Productivity Capabilities
        • +Warnings, Errors, Crashed, Confirm, etc.. messages in AutoPIPE
      • +Bentley AutoPIPE Nozzle (WinNOZL)
      • +Bentley AutoPIPE Vessel (powered by Microprotol)
      • +Bentley PlantFLOW
      • +Bentley PULS
    • Multi-lingual announcement from BENTLEY TECHNICAL SUPPORT.
    • Working at Home with AutoPIPE
    • +AutoPIPE Brand Learning Resources
    • +Attend a live meeting with an AutoPIPE Analyst

     
     Questions about this article, topic, or product? Click here. 

    01. PCF Translator FAQ & troubleshooting - AutoPIPE

    Comments, Questions, and Answers with PCF translator into AutoPIPE:

    Note:

    1. See PCF translator Help / manual for complete details

    2. How to create a PCF file - click here

    0: Install PCF translator

    1: Process aborted or crashed

    2: Translator Freezes / Not Responding / Disappears

    3: Warning message about  Flanges and Valves are set to weightless “Zero Weight” components

    4: "E880-1: Error in opening import batch file. File extension must be NTL" message appears

    5: No graphical elements found for the components

    6: Branch piping not connected to the main header pipe

    7: Imported pipe sizes are very Large or Small

    8: Imported file truncated pressure values

    9: Piping code, material, and components are not supported

    10: Imported branch connection are not connected correctly

    11: Status = "Incorrect Component Connection Tolerance Value" displayed

    12: All the pipe wall thickness values are very large

    13: Mapping a Line Number

    14: Mapping examples

    15: Parts of my PCF translated file are missing piping or components

    16: Imported flanges from a PCF file rotated 90 deg

    17: Reset the PCF translator PCFin.MAP file

    18: Piping was not connected

    19: Remove Cad Length

    20:  Cannot select a specific item from drop down listing when importing a PCF file 

    21: Filter out small bore piping from being imported into the model

    22: Bend radius units

    23: Bend Radius calculation

    24: Bend are shown as straight pipe

    25: Imported piping appears disconnected or not aligned

    Below are general questions and answers about the process of exporting an existing AutoPIPE model (DAT) to a PCF file, translate the newly created PCF file with the PCF translator back into an AutoPIPE model, and compare AutoPIPE results between before and after translation:

    Q1.   The expansion joint are not support in the current PCF translator

    A1. Support for Flex/Expansion Joints were implemented in PCF translator 1.0.0.24. Suggest to use the latest release of PCF Translator. Y

    Q2. The pipe is oriented 180 deg from original

    A2. Before export to PCF from AutoPIPE, In AutoPIPE  Go to Tools> Settings > Isogen Settings

    Change North arrow to +X then the coordinates will matched exactly

    Q3. Pressure and Temp are different from before to after, example: 10 deg & 100 psi converted to 0.0 deg  & 0.0 psi

    A3. This is a limitation in AutoPIPE PCF Export, which does not write Pressure and Temperature and hence default values are used.

    Q4. Pipe properties changed; wall thickness changed sch 160  changed to STD and Pipe material, from A335-P91 changed to A106-A

     A4. There is a limitation in AutoPIPE PCF Export could not correctly map the material and by default A106-A with STD wall thickness has been used. Adjust the map file as required to correctly map the material and wall thickness.

    Q5. Extra support (V-stop)  added to the converted file at origin point with anchor.

    A5. During first time Export to PCF. AutoPIPE write Anchors as a Support with SKEY 01AN and then on import this support component converted to an default support V-STOP. Manually delete V-Stop.

    Q6. Flanges converted for the expansion joint are in the wrong location.

    A6. This has been fixed in a newer version of the translator, upgrade to the latest version of PCF Translator,

    Q7. Tee SIF values are different (because of wall thickness issue above, Q4)

    A7. Yes, proper schedule has not been exported by AutoPIPE in PCF. update PCF map file accordingly.

    Q8 Bend radius is different

    A8. Bend length is exactly same but after import from PCF the actual radius has been written instead of "LONG"

    Q9  I cannot get the PCF translator to execute from the command line (Batch Processing) as mentioned in the help info, why?

    A9. This passage was not suppose to have been printed in the published documentation because this feature had never been added to the program. This information was removed in the new version of the documentation.

    See Also

    PCF Translator Issues

    Bentley AutoPIPE

    • PCF
    • import
    • AutoPIPE
    • Translator
    • Share
    • History
    • More
    • Cancel
    • Mike Dattilio Created by Bentley Colleague Mike Dattilio
    • When: Thu, Jul 18 2013 5:09 PM
    • Mike Dattilio Last revision by Bentley Colleague Mike Dattilio
    • When: Wed, Jan 4 2023 2:46 PM
    • Revisions: 79
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies