The following is being displayed while running analysis:
W774-47 One or more combinations are set to none,
why is being displayed and how to resolve
There are no load cases selected in any load sets specified, select Load> Static Analysis>, notice the last column of the grid, LOAD CASES, are there any loads specified?
Or
Illegal combination have been specified under Tool> Combinations with load cases that are not currently being analyzed.
Before running an analysis:
Select Tools> Model Constancy check> reduce the number of warnings to as few as possible
Select Tools> Design Check> reduce the number of warning to as few as possible
Confirm Load> Static analysis> all analysis sets where "Analyze" is enabled have at least one load case specified in the "Load Cases" column on the far right side of the grid.
When changing the number of Tools> Model Options> General> "Number of operating load conditions" from a larger value to a smaller one, may have deleted a load cases used in both analysis set and combination. Confirm Load> Static analysis> all analysis sets where "Analyze" is enabled have at least one load case specified in the "Load cases" column on the far right side of the grid.
Also, confirm Tools> Combination> all load cases specified on the Load Cases tab are correctly set in the model and checked on in the respective load sets to be analyzed. In addition, confirm all combinations on the Code/Non-Code tab are correct, especially any user created combinations where Auto Update is unchecked.