AutoPIPE Wiki Alias StressISO for AutoPIPE 09.06.01.xx and Lower - Stress Iso Export: There were some warnings and/or errors while executing ISOGEN
    • Sign In
    • -Pipe and Vessel Stress Analysis - Wiki
      • +ADL PIPE
      • -Bentley AutoPIPE
        • +- General Information about AutoPIPE
        • +- NEW User Guide for AutoPIPE
        • +- Technical Support - AutoPIPE
        • +Batch Processing, ITS, and ATS using AutoPIPE
        • AutoPIPE QA&R program
        • +Download - Install - Release Notes - AutoPIPE
        • +File / Model Management using AutoPIPE
        • +General - AutoPIPE
        • +Graphics - AutoPIPE
        • +Grids (Input & Results) - AutoPIPE
        • +Import and Export - AutoPIPE
        • +Known Issues in AutoPIPE (Enhancements, defects, etc..)
        • +Libraries - AutoPIPE
        • +License AutoPIPE -
        • +Loads and Load Sets - AutoPIPE
        • +Localization (Non-English Language) - AutoPIPE
        • +Modeling Approaches in AutoPIPE
        • +Modules (i.e. Flange Analysis, Spring Hanger Selection, Rotating Equip, TTA) in AutoPIPE
        • +Piping codes - AutoPIPE
        • +Post Processing - AutoPIPE
        • +Printing - AutoPIPE
        • +Reports - AutoPIPE
        • Security
        • +Settings - AutoPIPE
        • -Stress Isometrics - AutoPIPE
          • - How do I create a Stress Iso in AutoPIPE using OPIM?
          • +.OPIM Stress Isometric Troubleshooting Guide using AutoPIPE V8i 09.06.01.xx and higher
          • .Stress Isometrics features in AutoPIPE V8i 09.06.02.xx and higher
          • Alias StressISO for AutoPIPE 09.06.01.xx and Lower - Stress Iso Configuration files
          • -Alias StressISO for AutoPIPE 09.06.01.xx and Lower - Stress Iso Export: There were some warnings and/or errors while executing ISOGEN
            • Alias Stress Iso for AutoPIPE 09.06.01.xx and Lower - Errors / Warnings Detected
          • Alias StressISO for AutoPIPE 09.06.01.xx and Lower - Beam / Pipe trunnions are not displayed in StressISO
          • Alias StressISO for AutoPIPE V8i 09.06.01.xx and Lower
          • Alias StressISO Troubleshooting Tips for AutoPIPE 09.06.01.xx and Lower
          • Q0. What are the difference between a Stress Isometric and Fabrication Isometric using AutoPIPE?
          • Q1. What was the last version of AutoPIPE that supported Alias StressISO Isogen application?
          • Q2. Can you combine an older version with Isogen and new version of with OPIM in AutoPIPE?
          • Q3. Is the extra StressISO Add-on license required in order to create a Stress Isometric using AutoPIPE 09.06.02.06 or higher with the OpenPlant Isometrics manager?
          • Q4. Is it necessary to install OPIM prior to using AutoPIPE Stress Isometric feature?
          • Q5. Is Bentley going to have any conversion procedure for AutoPIPE Stress-Iso to OpenPlant Isometrics Manager (OPIM)?
          • Q6. Can a Stress Isometric be created without an additional OPIM license?
          • Q7. Can I open the AutoPIPE Isometric file from Windows Explorer without incurring over usage charges?
        • +Technology Productivity Capabilities
        • +Warnings, Errors, Crashed, Confirm, etc.. messages in AutoPIPE
      • +Bentley AutoPIPE Nozzle (WinNOZL)
      • +Bentley AutoPIPE Vessel (powered by Microprotol)
      • +Bentley PlantFLOW
      • +Bentley PULS
    • Multi-lingual announcement from BENTLEY TECHNICAL SUPPORT.
    • Working at Home with AutoPIPE
    • +AutoPIPE Brand Learning Resources
    • +Attend a live meeting with an AutoPIPE Analyst

     
     Questions about this article, topic, or product? Click here. 

    Alias StressISO for AutoPIPE 09.06.01.xx and Lower - Stress Iso Export: There were some warnings and/or errors while executing ISOGEN

    Applies To
    Product(s): AutoPIPE,
    Version(s): 2004, XM, & V8i
    Environment: N/A
    Area: Stress Iso
    Subarea:
    Original Author: Bentley Technical Support Group

    Problem:

    What do I do when the following appears?

    ---------------------------
    Stress Iso Export
    ---------------------------
    There were some warnings and/or errors while executing ISOGEN.
     Do you want to review messages:
    ---------------------------
    Yes   No  
    ---------------------------


     

     Answer:

    Press the "Yes" button.

    In a moment the AutoPIPE Viewer will be displayed with the following file:

    C:\ Bentley\ AutoPIPE V8i SELECTseries\ PISOGEN\ PROJECTS\ APIPEPROJ\FINAL\ OUTPUT\ FINAL.MES

    This file will provide details to the reason why the stress iso draw was or was not created. Fianl.MES file is updated each time after a Stres Iso command is invoked and drawing is created. Therefore it only contains information from the last successful run.

    The Final.MES file has multiple sections:

    > Header

    The header contains information about the current version of Isogen installed.

    example:

    Personal ISOGEN : VERSION 7.3.0 (Full)

    *** IDFGEN VERSION 8.3.0 (Build 08) ***

    Reading File: ISOGEN.PCF

    > Errors / Warnings Detected

    Detailed listing of Errors or Warnings including Message Identifier, Component Type, Coordinates, PCF Line Number, and additional information about the issue under Message Text.

    Note: the coordinates are listed in order of,
    East/West (default global Z), North / South (default global X), Up/down (default global Y)

    > Connection Diagnostic Report FOR ISOGEN.PCF

    A report listing all the components in the model with a unique PCF reference number, component type, coordinates of start point (#1) and end point (#2), Bore (Nominal) Diameter, and connection sequence.

    Note: the coordinates are listed in order of, End Point #1, End Point #2
    East/West (default global Z), North / South (default global X), Up/down (default global Y)

    > Exported Drawings Create with Filepath Name(s)

    Isogen will attempt to create a drawing file based on the model information. It will attempt multiple passes at the file creation. For each attempt that successfully creates a drawing file the entire file name path is printed in the report.  example:

     OUTPUT STAGE OF DRAWING 1_PASS_1

             **** ISOPLOT ****

     THE FOLLOWING DRAWINGS ARE IN PLOTFILE  C:\Users\mike.dattilio\Desktop\70000290 - NMaron\1_PASS_1.DXF
              DRG.   1   /1_PASS_1 PLOTTED

     

    See Also

    Bentley AutoPIPE

    External Links

    Bentley Technical Support KnowledgeBase

    Bentley LEARN Server

    Comments or Corrections?

    Bentley's Technical Support Group requests that you please submit any comments you have on this Wiki article to
    the "Comments" area below. THANK YOU!

    • Alias StressISO
    • AutoPIPE
    • Share
    • History
    • More
    • Cancel
    • Mike Dattilio Created by Bentley Colleague Mike Dattilio
    • When: Wed, Aug 7 2013 4:55 PM
    • Mike Dattilio Last revision by Bentley Colleague Mike Dattilio
    • When: Mon, Apr 20 2015 4:06 PM
    • Revisions: 4
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies