What are some general Stress Iso warnings and how to resolve them?
UNABLE TO POSITION: 'REFERENCE DIMENSION'
UNABLE TO POSITION: 'Support'
UNABLE TO POSITION: 'MESSAGE-ROUND'
1. See the following file to be sure that no known issues are present in the current model; especially A1.Disconnected Pipeline:
C:\ Bentley\ AutoPIPE V8i SELECTseries\ StressISO_Troubleshooting.pdf
2. Known issue, changing segment at a reducer start point or end point.
The following has been logged:
TFS-D123552: Stress ISO Export failed if near/far end of REDUCER were on segment continuation point
Fix, select node point shared by both egments, (ex. W15) and then join segment by going menu Edit> Segment> Join.