Description:
Under Wind Profile (Height and Wind Pressure), suggest to increase from maximum eight (8) sets of data to at least ten (10) sets of data to capture larger range of available data .
Steps to repeat:
1. Open Walkthru model
2. Open the Segment tab of Review Component Data dialog and uncheck "Apply wind" for all segments
3. Open the Wind load dialog
Observe that "All segments exposed to wind" checkbox is unchecked.
4. Enable the "All segments exposed to win" checkbox and pres OK on the Wind dialog
5. Open the Segment tab of Review Component Data grid
Note that the Apply Wind checkbox for all the segments are still unchecked.
Development Project: 10.00.xx
Description: Add IBC 2009 to the wind profiles
Development Project: TBD
The Ground Elevation for Wind is always entered in Feet, regardless of the model units selected in General Model Options Dialog.
Avoidance:
Always convert Ground Elevation for Wind to Feet before entering on the Wind dialog
Development Project: 9.6.0.19
Description: Add option to run non-linear analysis with friction = 0 for Wind load cases .
Add STAAD wind and seismic load generators which includes ASCE-7, 2002 and ASCE-7, 2010 codes.
Description: Add input grid for wind loading .
Development Project: TBD.