You are currently reviewing an older revision of this page.
The following is displayed in model consistency check report:
W726-7: Pipe diameter change without a reducer at point XXX
This warning message is displayed whenever there is a difference in pipe properties OD or wall thickness between two sucessive points in a model without a reducer.
Insert a reducer between the 2 different pipe properties.
As the designer, accept the warning as OK, and ignore it as the joint is correctly modeled. Insert a user Joint type / SIF added as needed.
This warning will appear when modeling a tee where 1 segment makes up both 1/2 the run of a Tee and the branch of a Tee, while the 2nd segment makes up the remanding 1/2 the run of a Tee.
This modeling technique is OK, but suggest to fix this tee with the instructions on the following WIKI here in order to remove this warning from the Model Consistence Check report.
Warnings Messages displayed in AutoPIPE
Bentley AutoPIPE
Bentley Technical Support KnowledgeBase
Bentley LEARN Server
Bentley's Technical Support Group requests that you please submit any comments you have on this Wiki article tothe "Comments" area below. THANK YOU!