The Load> Static Analysis Sets command allows the user to define multiple static analyses (analysis sets) and provide references to these results from separate analyses during post-processing. Analyze > Static or will analyze all selected static analysis sets.
The Static option in the Analyze menu enables the user to perform all the selected static analysis sets considering any scenarios of gravity and thermal expansion loads, plus wind loads and/or static earthquake loads if they have been defined.
From inside AutoPIPE with a model opened, select Load> Static Analysis sets... after the screen appears press the "HELP" button for details on all the key features available on the dialog.
To define load cases to be added to a specific analysis set, highlight a row by left clicking the mouse on the first square in the row, the row should be highlighted black with white lettering, now left click the "Modify" button. In a moment the"Static Analysis Load Cases" dialog should appear. AutoPIPE only activates load case input fields for currently defined load cases. Again press the "HELP" button for details of features available on this dialog screen.
Loads and Load Sets - AutoPIPE