Steps to Repeat:
1.Open MSRS_Example model2.Delete imposed displacement at point 173.Running "Consistency Check" reports "W2143-29:Response spectrum case R1 has support group 3 that is no longer defined in model."4.Running "Analyze All" command gives message "E801-24: Number of MSRS groups is inconsistent with SAM case"5.Open dynamic analysis dialog and go to Response Spectrum tab6.Click on define button in Spectra column7.Notice that the support group 3 is not available.8.Press OK, and again press OK to close dynamic analysis dialog.9.Run consistency check and analyze all commands and notice that the message is still given.
Workaround:
- Open dynamic analysis dialog- Go to Response Spectrum tab.- Click on define for load sets reported in consistency check- Change a single scale factor or just write same value again.- Click apply button & then click OK.- Click OK to close dynamic analysis dialog.- Run Consistency check and Analyze All commands and notice that no message is given this time.
Found in build: 09.06.01.11
Updated Version: TBD
Description:
Include buoyancy load to copy from one model to another model
After the rotate dialog appears, add a button that enables the user to specify a rotate point using the pc mouse instead of keying in a value.
Rotate geometry, supports, local and global static loads.