You are currently reviewing an older revision of this page.
The following Dynamic Analysis enhancements have been logged for inclusion into a future version of AutoPIPE:
Note: if an enhancement has not been added to the program, log an Service request for that enhancement. The more requests logged per an enhancement, the quicker the CAE development team will add that feature to the program.
Description:
For time history post processing plots, add feature to enable user to specify x-axis limit > 1 sec.
Corrected Version: TBD
Corrected Version : TBD
Similar to Load> Fluid Transient and would call Load> Slug flow where User enters: Slug velocity, slug length, liquid density, starting node point, and ending node point of slug in fluid transient. Program generates TIH and THL files. Module would automatically calculate the slug load magnitude, create the time histories for bends and apply them accrodingly.
Program should block dynamic analysis if first analysis set not analyzed. There is an internal limitation of the program that the first static analysis set should always be selected for analysis if there is any dynamic analysis to be performed for the model. AutoPIPE historically had only 1 load set prior to 9.1.0, all of the definitions related to dynamic load cases etc used to be associated with this single load set. In the new system – this older load set is mapped to the first static analysis set.
Corrected Version: 9.6.0.10
Enhancements Requests and Logged Defects
Bentley AutoPIPE
Bentley Technical Support KnowledgeBase
Bentley LEARN Server
Bentley's Technical Support Group requests that you please submit any comments you have on this Wiki article tothe "Comments" area below. THANK YOU!