E801-3: No static load cases specified


Applies To
Product(s):AutoPIPE,
Version(s):ALL
Area: error
Original Author:Bentley Technical Support Group

Problem:

The following is displayed in AutoPIPE when trying to perform an analysis:

---------------------------
Error
---------------------------
 E801-3:   No static load cases specified
---------------------------
OK  
---------------------------
 

Solution:

 The problem is located in Load> Static Analysis sets> there is no load case defined

or

Note: If Analysis set is for a Hydroload test, user must open Hydrotest Load Properties dialog, update settings as needed, and press OK button for the Load cases to appear on the Analysis Sets dialog above. 

Be sure that at least one load case has been selected for analysis as shown below:

or

Notes:

1. in order to select a load case press the Modify button

2. When adding a Hydrotest, be sure to open the Hydrotest Load Properties dialog make adjustments and press OK button before analyzing. 

 In addition, check the Tools> Model Options> General> Edition year is not blank:

If blank, select a valid Edition year from the drop down listing.

See Also

Error Messages

Bentley AutoPIPE