When importing an ADL PIPE coverted ADI to NTL file into AutoPIPE The following is displayed:
---------------------------Confirm--------------------------- Import process successful. Review warning messages :---------------------------Yes No Cancel ---------------------------
Press OK button, AutoPIPE appears to be starting and the following occurs:
Bentley AutoPIPE Application Bentley AutoPIPE Application has stopped working. A problem caused the program to stop working correctly. Windows will close the program and notify you if a solution is available.[Close program]
Bentley AutoPIPE Application
Bentley AutoPIPE Application has stopped working.
A problem caused the program to stop working correctly. Windows will close the program and notify you if a solution is available.
[Close program]
Only option is to press "Close Program" button.
1. Check the ADL file to be sure all the information is correct
Example:
SENO ISO RCIC-659-1.2PI 1 116.625 .562 27.8 6.23 180. 3.89RU 1 3002 0.5
Note: pipe instruction format is missing the second node name.
Should be:
PI 1 3002 116.625 .562 27.8 6.23 180. 3.89
2. The piping code year specified n ADL PIPE is available in AutoPIPE version importing the file into.
ADLPipe Translator - AutoPIPE
Bentley AutoPIPE