    • Q. How to Set the Default Material Database into AutoPIPE Vessel?

      Mike Dattilio
      Mike Dattilio
      1. Select File > Preference to display the Preference Properties dialog. 2. Select the Default Path tab. 3. From the Material Database path and name field, press Browse to display the Open dialog. 4. Navigate to the appropriate database file (.emdm…
      • over 2 years ago
      • AutoPIPE
      • AutoPIPE Wiki
    • 03. How to add a new material into AutoPIPE Vessel

      Mike Dattilio
      Mike Dattilio
      1. Version 42 and higher 2. Version 41 and lower Q. How to load a material database - click here Q. How to set the default material database - click here Q. Time required to add a new material - click here See Also Support Solutions and FAQ…
      • over 1 year ago
      • AutoPIPE
      • AutoPIPE Wiki
    • 01. How to add new material to material database, writing added material to database and loading database in AutoPIPE Vessel v42 and higher?

      Mike Dattilio
      Mike Dattilio
      Applies To AutoPIPE Vessel Product(s): AutoPIPE Vessel Version(s): all Area : Material Database Original Author: Bentley Technical Support Group Version v42 and higher Problem: …
      • over 1 year ago
      • AutoPIPE
      • AutoPIPE Wiki
    • 06. How to Input user defined material factor of safety for changing design allowable stress as per various codes in AutoPIPE Vessel?

      JamieP
      JamieP
      Applies To Product(s): AutoPIPE Vessel Version(s): V8i Area: Library Original Author: Bentley Technical Support Group Question: Input user defined material factor of safety for changing design…
      • over 3 years ago
      • AutoPIPE
      • AutoPIPE Wiki
    • 02. How to add new material to material database, writing added material to database and loading database in AutoPIPE Vessel v41 and lower?

      Mike Dattilio
      Mike Dattilio
      Applies To AutoPIPE Vessel Product(s): AutoPIPE Vessel Version(s): all Environment: N/A Area : Material Database Original Author: Bentley Technical Support Group Problem: How to…
      • over 2 years ago
      • AutoPIPE
      • AutoPIPE Wiki
    • Material, Material Database, and Default Libraries

      Tanaji Gaikwad
      Tanaji Gaikwad
      01. "Not a valid Material Database load it manually" message appears when using AutoPIPE Vessel, why and how to avoid? 02. How are nominal design stresses calculates in AutoPIPE for a material? 03. How to add new material to material database, writing…
      • 2 months ago
      • AutoPIPE
      • AutoPIPE Wiki
    • 01. "Not a valid Material Database load it manually" message appears when using AutoPIPE Vessel, why and how to avoid?

      JamieP
      JamieP
      Applies To Product(s): AutoPIPE Vessel Version(s): ALL Area: Material Database Date Logged & Current Version March 2020 41.04.00.013 Problem: When we open Autopipe, the following is displayed Not a valid…
      • over 3 years ago
      • AutoPIPE
      • AutoPIPE Wiki
    • 02. How are nominal design stresses calculates in AutoPIPE for a material?

      JamieP
      JamieP
      Applies To Product(s): AutoPIPE Vessel Version(s): ALL Area: Material database Date Logged & Current Version March 2020 41.04.00.013 Problem: How are the nominal design stress under normal operating conditions…
      • over 3 years ago
      • AutoPIPE
      • AutoPIPE Wiki
    • 05. How to delete an existing material from the database?

      JamieP
      JamieP
      Applies To Product(s): AutoPIPE Vessel Version(s): ALL Area: Date Logged & Current Version March 2020 41.04.00.013 Problem: How to delete an existing material from the database? Solution: Select the material…
      • over 3 years ago
      • AutoPIPE
      • AutoPIPE Wiki
    • 04. How to create a small material database for a few select list of materials and merge it to another database?

      JamieP
      JamieP
      Applies To Product(s): AutoPIPE Vessel Version(s): ALL Area: Date Logged & Current Version March 2020 41.04.00.013 Problem: How to create a small material database for a few select list of materials and merge…
      • over 3 years ago
      • AutoPIPE
      • AutoPIPE Wiki
    • Q. Unable to read section database...message appears in AutoPIPE

      Mike Dattilio
      Mike Dattilio
      Applies To Product(s): AutoPIPE Version(s): ALL; Area: Message Date Logged & Current Version Feb. 2019 12.00.00.14 Problem: The following message dialog appears when trying to view insert a beam property. …
      • over 4 years ago
      • AutoPIPE
      • AutoPIPE Wiki
    • "Program failed to generate SQlite Database..." message appears in AutoPIPE

      Mike Dattilio
      Mike Dattilio
      Applies To Product(s): AutoPIPE Version(s): ALL; Area: Report Date Logged & Current Version Sept. 2018 11.04.00.10 Problem: The following message appears when exporting a WORD report from AutoPIPE -----…
      • over 2 years ago
      • AutoPIPE
      • AutoPIPE Wiki
    • "Error in writing Point file.Type mismatch... " message appears in AutoPIPE , why?

      Mike Dattilio
      Mike Dattilio
      Applies To Product(s): AutoPIPE Version(s): ALL; Area: Error Message Date Logged & Current Version April. 2018 11.03.00.08 Problem: The following appears in AutoPIPE when exporting a model input listing: …
      • over 3 years ago
      • AutoPIPE
      • AutoPIPE Wiki
    • "Error in writing Soil file.Type mismatch... " message appears in AutoPIPE , why?

      Mike Dattilio
      Mike Dattilio
      Applies To Product(s): AutoPIPE Version(s): ALL; Area: Error Message Date Logged & Current Version April. 2018 11.03.00.08 Problem: The following appears in AutoPIPE when exporting a model input listing: …
      • over 3 years ago
      • AutoPIPE
      • AutoPIPE Wiki
    • "Error in writing Section ID file.Type mismatch... " message appears in AutoPIPE , why?

      Mike Dattilio
      Mike Dattilio
      Applies To Product(s): AutoPIPE Version(s): ALL; Area: Error Message Date Logged & Current Version April. 2018 11.03.00.08 Problem: The following appears in AutoPIPE when exporting a model input listing: …
      • over 3 years ago
      • AutoPIPE
      • AutoPIPE Wiki
    • "Error in writing Valve file.Type mismatch..." message appears in AutoPIPE , why?

      Mike Dattilio
      Mike Dattilio
      Applies To Product(s): AutoPIPE Version(s): ALL; Area: Error Message Date Logged & Current Version April. 2018 11.03.00.08 Problem: The following appears in AutoPIPE when exporting a model input listing: …
      • over 3 years ago
      • AutoPIPE
      • AutoPIPE Wiki
    • "Error in writing Tee file.Type mismatch... " message appears in AutoPIPE , why?

      Mike Dattilio
      Mike Dattilio
      Applies To Product(s): AutoPIPE Version(s): ALL; Area: Error Message Date Logged & Current Version April. 2018 11.03.00.08 Problem: The following appears in AutoPIPE when exporting a model input listing: …
      • over 3 years ago
      • AutoPIPE
      • AutoPIPE Wiki
    • "Error in writing Pres/Temp/PipeID file.Type mismatch... " message appears in AutoPIPE , why?

      Mike Dattilio
      Mike Dattilio
      Applies To Product(s): AutoPIPE Version(s): ALL; Area: Error Message Date Logged & Current Version April. 2018 11.03.00.08 Problem: The following appears in AutoPIPE when exporting a model input listing: …
      • over 3 years ago
      • AutoPIPE
      • AutoPIPE Wiki
    • 03-l: Export Database (MDB)

      Mike Dattilio
      Mike Dattilio
      Comments, Questions, and Answers about exporting database files from AutoPIPE: 1. Can AutoPIPE export a database file to Microsoft Access or Excel? Answer : AutoPIPE 09.05.01.02 and higher can export both input database and results database to Access…
      • over 5 years ago
      • AutoPIPE
      • AutoPIPE Wiki
    • Export SQLite Database - AutoPIPE Technology Preview

      Mike Dattilio
      Mike Dattilio
      Applies To Product(s): AutoPIPE Version(s): CONNECT Environment: N/A Area: Technology Preview Original Author: Bentley Technical Support Group Date Logged & Current Version March. 2017 11.00.00.22 …
      • over 4 years ago
      • AutoPIPE
      • AutoPIPE Wiki
    • View related content throughout AutoPIPE
    • More
    • Cancel
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies