46. What methods are used to calculate the K factor from ASME VIII Div 1, appendix EE for use in a Pressure Vessel designed in AutoPIPE Vessel?
Mike Dattilio
Answer: Given the vessel is 6040mm dia with a wall thickness = 20mm and Limpet / Half pipe coli with a pitch of 150 mm and 40 mm radius. Referencing, ASME VIII Div 1, appendix EE, figure EE-2 (DN80), the K factor would be read, but parameter D is…
11 months ago
AutoPIPE
AutoPIPE Wiki
01. Does the calculation of a body flange according to ASME VIII, div 1, consider a rigidity criterion in an AutoPIPE Vessel model?
Tanaji Gaikwad
Applies To Product(s): AutoPIPE Vessel Version(s): ALL Area: Report Date Logged & Current Version June 2018 40.06.00.07 Problem: Does the calculation of a body flange according to ASME VIII, div 1, consider…
2 months ago
AutoPIPE
AutoPIPE Wiki
01. What is the formula used for hydro-test pressure calculations per CODAP Div. 1 used for Shell and Tube Heat Exchangers in AutoPIPE Vessel?
Tanaji Gaikwad
Applies To Product(s): AutoPIPE Vessel Version(s): ALL Area: Calculations Date Logged & Current Version Sept. 2017 40.04.00.08 Problem: Formula for calculation of hydro-test pressure as per CODAP Div.1 is: …