Q. ANSI Check Flange Loading Calculations, for some load cased Operating pressure appears to not be added to Equivalent pressure in AutoPIPE, why?
Mike Dattilio
Applies To Product(s): AutoPIPE Version(s): ALL; Area: Date Logged & Current Version April 2020 12.03.00.17 Problem: ANSI Check Effective flange pressure equals P operating plus P eq. For a number of load cases…
8 months ago
AutoPIPE
AutoPIPE Wiki
W2164-204: The following flange(s) do not consider corrosion... warning message occurred in AutoPIPE, why?
Mike Dattilio
Applies To Product(s): AutoPIPE Version(s): ALL; Area: Warning Date Logged & Current Version Feb 2020 12.02.00.14 Problem: The following is displayed when using AutoPIPE * * * W A R N I N G - MODEL * * * W2164…
over 1 year ago
AutoPIPE
AutoPIPE Wiki
"The value must be equal to the inside diameter of the pipe" Flange Analysis message appears when running AutoPIPE's Flange Analysis module
Mike Dattilio
Applies To Product(s): AutoPIPE Version(s): All Environment: N/A Area: Flange Analysis Original Author: Bentley Technical Support Group Date Logged & Current Version …
over 1 year ago
AutoPIPE
AutoPIPE Wiki
"The value must be smaller than the outside diameter" Flange Analysis message appears when running AutoPIPE's Flange Analysis module
Mike Dattilio
Applies To Product(s): AutoPIPE Version(s): All Environment: N/A Area: Flange Analysis Original Author: Bentley Technical Support Group Date Logged & Current Version …
over 5 years ago
AutoPIPE
AutoPIPE Wiki
"The value must be equal to the outside diameter of the pipe" Flange Analysis message appears when running AutoPIPE's Flange Analysis module-
Mike Dattilio
Applies To Product(s): AutoPIPE Version(s): All Area: Flange Analysis Original Author: Bentley Technical Support Group Date Logged & Current Version Feb. 2016 10.00.00.10 Problem…
over 2 years ago
AutoPIPE
AutoPIPE Wiki
Q. Flange data does not seem to be correct in AutoPIPE flange analysis module?
Mike Dattilio
Applies To Product(s): AutoPIPE, Version(s): ALL Area: Analysis Original Author: Bentley Technical Support Group Problem: Using Tools> Flange Analysis. Look-up dimensions for a 30" 150# B16…