20. How to define shell length in different types of Heat Exchanger in AutoPIPE Vessel
JamieP
Applies To Product(s): AutoPIPE Vessel Version(s): ALL Area: Modeling Date Logged & Current Version Sept. 2017 40.04.00.08 Problem: How to define shell length in different types of Heat Exchanger Solution…
over 3 years ago
AutoPIPE
AutoPIPE Wiki
24. Heat Exchanger Pass Partition Plate Modification
JamieP
The pass partition plate for shell side and tube side can be edited by clicking on "Show Accessories List" icon in the Bundle Layout dialog box: Then click on Partition Plates: You can modify some dimensions and make edits on the following dialog…
over 3 years ago
AutoPIPE
AutoPIPE Wiki
12. How can I insert the shell connection on the head of a heat exchanger in AutoPIPE Vessel?
JamieP
Applies To Product(s): AutoPIPE Vessel Version(s): V8i Environment: N/A Area: Modeling Original Author: Bentley Technical Support Group Date Logged & Current Version August 2016 40.02.00.08 Problem…
over 3 years ago
AutoPIPE
AutoPIPE Wiki
14. How to model customized base plate of a Saddle support for Shell and Tube Heat Exchanger in AutoPIPE Vessel?
JamieP
Applies To Product(s): AutoPIPE Vessel Version(s): V8i Area: Modeling Original Author: Bentley Technical Support Group Date Logged & Current Version August 2016 40.02.00.08 Problem: The user would want…
over 3 years ago
AutoPIPE
AutoPIPE Wiki
30. The definition of the characteristics of the gasket under the pass partition in a heat exchanger is not possible
JamieP
Answer: As usual in AutoPIPE Vessel, the number of the chamber must be correct. You must check that the components on the tubes side are in the chamber number 2.
over 3 years ago
AutoPIPE
AutoPIPE Wiki
Error Code 29 - Equivalent stress in the tubes exceeded
JamieP
Q. I am getting the following error messages: equivalent stress in the tubes exceeded longitudinal stresses in the tubes exceeded. How do I solve these issues? Ans: Please see the following wiki page: http://communities.bentley.com/products…
over 3 years ago