How to Disable the ModelServer Login using OpenPlant Isometrics Manager With Managed Workspace


Applies To 
Product(s):OpenPlant Isometrics Manager
Version(s):08.11.09.XXX (SS5) | 08.11.11.XXX (SS6)
Environment: Windows 7/8.1/10 (64 bit)
Area: Open/Save
Subarea: -
Original Author:Harpreet Singh, Bentley Product Advantage Group

Background

While launching OpenPlant Isometrics Manager with Projectwise managed workspace below dialog shows up for selecting OpenPlant ModelServer Project.


If user doesn't have model server project, they can suppress this dialog by one setting in managed workspace.

Steps to Accomplish

Setting the Variable in Project CSB 

  1. Go to project node and select your project CSB.



  2. Double click on CSB to open the properties dialog.



  3. In the configuration tab, click green '+' sign and select Add Variable option.



  4. Add below variable in dialog as shown.



  5. Add the value for the variable as 1.



  6. Click OK on all the subsequent dialogs and apply the changes.
  7. Launch OpenPlant Isometrics Manager and verify result.

Setting in OpenPlant Project Administrator

  1. Launch OpenPlant Project Administrator.
  2. Add your managed project in project administrator.



  3. Toggle on highlighted option and click Save button.



  4. Launch OpenPlant Isometrics Manager to verify the result.

See Also