To Fix the Display Issue for Fasteners in OpenPlant Modeler


 

Applies To 

Product(s):

OpenPlant Modeler

Version(s):

08.11.11.87

Environment: 

Windows 7/8/10 (64 bit)

Area: 

Component

Subarea: 

Placement

Original Author:

Faisal Khan, Bentley Product Advantage Group

Overview

To fix the display issue for fasteners in OpenPlant Modeler.

Problem Description

In OpenPlant Modeler, for flanged component fastener graphics are not populating properly. Though in connectivity check there is no error.



Reason

In OpenPlant Modeler, components are fetched from the spec. Hence it must be set True for option IsFastenerSpec Driven.


Steps to Resolve

  1. Launch Bentley Class Editor.
  2. Go to File menu option and select Open



  3. Open OpenPlant_3D.01.07ecschema.xml from “C:\ProgramData\Bentley\OpenPlantModeler V8i\WorkSpace\Projects\[Project Name]\Dataset\schemas”



  4. Select “OpenPlant.01.07.ecschema.xml” schema in “Locate a missing reference OpenPlant.01.07 for schema OpenPlant_3D.01.07” dialog from “C:\ProgramData\Bentley\OpenPlantModeler V8i\WorkSpace\OPModeler\schemas” and Open



  5. Right click on OpenPlant_3D in Class editor and select “Supplement Schema”



  6. Select “Add” from “Specify Supplemental Schemas” dialog



  7. Select "OpenPlant_3D_Supplemental_ModelingViews.01.07.ecschema.xml" and "OpenPlant_3D_Supplemental_Modeling.01.07.ecschema.xml" schemas from “C:\ProgramData\Bentley\OpenPlantModeler V8i\WorkSpace\Projects\[Project Name]\Dataset\schemas” and press Open



  8. After adding supplemental schemas, Click “OK” to “Specify Supplemental Schemas” dialog.



  9. A “Locate a missing reference OpenPlant_CustomAttributes.08.11 for schema OpenPlant_3D_Supplemental_Modeling.01.07” dialog will pop up, select “OpenPlant_CustomAttributes.08.11.ecschema.xml” schema from “C:\ProgramData\Bentley\OpenPlantModeler V8i\WorkSpace\OPModeler\schemas” and select Open.



  10. It will supplement the schema. Once it got supplemented schema will be shown as OpenPlant_3D [Supplemented] in Class Editor



  11. Press “Find Class” icon in Class Editor, write “Joint” in “Search For” field in “Find Class” Dialog and press Search Button



  12. Double click on “Joint” or Select Joint click on “Go To”



  13. Search Joint Name as FLANGE_JOINT and Expand the Fastener Section



  14. Change “Is Fastener Spec Driven” value to “True



  15. Save the changes and close Class Editor



  16. Launch OpenPlant Modeler.
  17. Select the project in File Open dialog and open a File



  18. Place some flanged components and you will see Fasteners (Gaskets, Bolts) getting placed in drawing 

Still a Problem?

If above problem still persist, then please create a Service Request and contact the Bentley Product Advantage group.  Please include a list of all relevant details to get in depth analysis for a solution or workaround. 