Error: Mapping of component not found, Class Name: BASE_AT_LUG_W_BOLT


Applies to
Product(s):OpenPlant Isometrics Manager
Version(s):08.11.11.XXX (SS6)
Environment:Windows 7/8.1/10 (64-bit)
AreaErrors, Logs, Messages, Crashes
Subarea
Original AuthorSwapnil Joshi, Bentley Product Advantage Group=

Background

The schemas do not have mapping of AutoPLANT Class AT_LUG_W_BOLT with OpenPLANT Piping Fastener Bolt Wafer Class. Hence we cannot generate the isometric of the model and get following error.

Steps to Resolve

  1. Launch Bentley Class Editor.



  2. Open schema OpenPlant_3D.01.07 and supplement with OpenPlant_3D_Isometrics_IsoExtractor schema.



  3. Search for BOLT in the classes.



  4. Expand the BOLT node and select Piping Fastener Bolt Wafer.



  5. In the class tab, add the entry in the AutoPLANT_PDW_Class_Map.



  6. Navigate to the Bolt class. In the Bolt class go to AutoPLANT_PDW_Catalog_Class_Map. Add the entry as shown below.

    Class Name: AT_LUG_W_BOLT
    Module Name: BASE
    GType BOLT
    SType LUG



  7. Save the schemas and regenerate the isometric. This time there will be no error in generating isometric.

See Also

communities.bentley.com/.../errors-logs-messages-crashes---openplant-isometrics-manager-for-autoplant

Still a Problem?

If the above problem still persist, then please create a Service Request and contact the Bentley Product Advantage Group. Please include a list of all relevant details  to get in depth analysis for a solution or workaround.