When generating an Iso drawing from AutoPLANT Piping model the error "Plotfile-Prefix must have trailing path delimiter" appears in the Export Progress dialoge and an Isogen DWG or DXF is not created.
The "Plotfile-Prefix must have trailing path delimiter" error is caused because the backslash "\" delimiter was dropped from the PLOTFILE-PREFIX path record in the isogen.fls file. To correct the error a backslash "\" needs to be added to the end of the PLOTFILE-PREFIX record.
Use the following steps using the SAMPLE_IMPERIAL project and Final Style as an example to correct the error.
Please note that the project and style folder may change depending on the project and style in use.
Product TechNotes and FAQs
Plant TechNotes And FAQs
Bentley Technical Support KnowledgeBase
Bentley LEARN Server
Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!