AP OPIM - Spool break
Maggie Zhang
Is it possible to set spool break on field weld? or spool break when specific attribute changes? For example, a long pipe is modeled in two pieces with a field weld, we want to identify it as two spools. Is this possible? Thanks, Maggie
over 6 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
AP OPIM - Victaulic Coupling behave differently while placing order differently
Maggie Zhang
When placing Vic coupling, ie, Vic Coupling Rigid 07, in different way, it shows and differently in OPIM ISO op 1 - place a vic pipe, place a rigid 07 coupling, place another vic pipe - vic coupling class is AT_COUP_RIGID07 op 2 (most people…
over 6 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
OPIM - Tapping connection sizes limitation?
Maggie Zhang
It seems there is a limitation on size when doing tapping. When I have larger different on tapping sizes (such as 2"x1"), OPIM has no problem, but when tapping sizes different is less or equal to 1/2" (such as 2"x1+1/2" or 1"x3/4"), OPIM failed. Is…
over 7 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
AP OPIM - OPIM hang after run trying to generate ISO on multi bend component
Maggie Zhang
Hi, Yesterday I ran into a hang issue on OPIM. I tried to generate ISO via OPIM in AutoPLANT, but it stopped on "Export Progress" window and telling "Preparation of data for OPIM", and OPIM manager never pop-up. And after this failing run, no other…
over 7 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
AP-OPIM - Material list text width factor
Maggie Zhang
I am trying to figure out where to set width factor for the MText of material list after ISO is generated and converted to DWG. I have tried to change the ration of Height and Width of TextNode in isoseed file but with no luck, no matter what I set, the…
over 7 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
AP-OPIM - Model Name in ISO
Maggie Zhang
I need to get 3D model name to show in OPIM Iso output. I read thread Capturing the AutoPLANT model name when extracting an iso with OPIM but suggested solution does not work on my company setup. And then I was try to make doc_name as relationship object…
over 7 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
OPIM - Part ID in Stress ISO
Maggie Zhang
Hi, Currently I deleted the report text node to remove material report but I cannot find the option/ switch to remove Part ID in the ISO image. Is it a way to hide Part ID in Stress ISO? Thanks, Maggie
Answered
over 7 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
AP OPIM - null reference
Maggie Zhang
When I tried to run OPIM from AutoPLANT on a single pipe, component exportion looked OK, but get an null reference exception. Where I can find out what's the problem in order to fix it. Thanks, Maggie
over 7 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
DISPLAY OF RATING ONTO REPORT IN OPIM
Guy Guerin
Greetings, I cant get the Rating of either bolts, flanges, etc to appear on the report (bom), whist I can however get any field to appear. I modified the class and report file as indicated in the OPIM help pages but it doesn't seem to work for Rating…
Answered
over 7 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
Capturing the AutoPLANT model name when extracting an iso with OPIM
Tyler Pollon
Hi there, I'm looking for a way to grab the AutoPLANT model name that the iso was extracted from when using OPIM, and placing that value into the iso as text similar to the txt2node & node2da methods. Thanks, Tyler
Answered
over 7 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
OPIM - Random fastener error on manual partial selection
Maggie Zhang
Recently I met an issue that when running OPIM in AutoPLANT with manual selection. If I manually select patial of the process line, even just a piece of pipe or a reducer, I got an error on fasterner, like weld, gasket, sometimes it says unconnected Components…
over 7 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
AP OPIM - pipeline end coordinations
Maggie Zhang
Hi, Is it a way to force coordination output on all ends of a process line? Originally, I thought it is a random case, but it looks like it happen often, especailly when one end is opened (no connection component). Any way to config or fix it? …
Answered
over 8 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
AP OPIM - Text Comments location is wrong on fittings
Maggie Zhang
Previously I put text comments on pipe, and they looked OK. However, when I put a comment text on a branch end, such as a plug, it points to a strange location. Originally, thought it might something in my customization so I switched to the sample MMetric…
over 8 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
AP OPIM - Valve operator spindle direction?
Maggie Zhang
I am trying to show valve operator spindle direction, but I cannot find the setting. I tried to enable valve operator label, but it only shows operator name, like "HAND_WHEEL" (expecting SPINDLE NORTH or SPINDLE UP, etc) . How and where can I do the setting…
over 8 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
AP OPIM - Tapped point of bleed ring in ISO
Maggie Zhang
Hi, When I ran ISO on a bleed ring with tap port, the tapping point show in middle of bleed ring symbol instead of edge of bleed right. Is any settings I can set to make it show properly? Also why bleed ring show as Flange in Part ID? Can I split…
Answered
over 8 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
AP OPIM - Bolt length in BOM
Maggie Zhang
It looks like the bolt length has some length sensitive, some length can output as inches, and some not - remaining in mm. Anything I can do on this? Thanks, Maggie
over 8 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
AP OPIM - Multiline control valve tag
Maggie Zhang
I tried to display control valve tag in ISO image and it did. However, it displayed as one line instead of multi-lines. Can someone help? Thanks, Maggie
Answered
over 8 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
RE: OPIM - Linetype for continued/existing components
Rahul Kumar
Hello Maggie, This is possible with latest 08.11.09.564 version only. See example#2 discussed in wiki link refer below: http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/23419.how-to-user-overrides…