Moving an object (tank) in OPM after it has been worked on in AECOSim
gary Nichols
I have several tanks modeled in OPM SS6, but because OPM doesn't give the option for angle iron legs (OPM only does round or square legs) I have our structural designer add the legs in AECOSim SS6. After he adds the legs I can't move the model in the…
over 6 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
OpenPlant Specification Generator
Mike.McGinnis
Does anyone know if there is any training on the LEARN server for working with SpecGen? Specifically, the catalog editor. Creating a new catalog.mdb Thanks
over 6 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
OPM User defined Valves Insulation
peter sande
User defined valves do not seem to show Insulation. Are we missing something?
over 6 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
Problems about Shared Cell within OPM
Joe Zou
Hey guys, In some actual cases, say a main pipeline with dozens of duplicated branches which are completely the same. Consequently, we did try to use Shared Cell. But found: 1, When the PIPING_COMPONENT s are made as normal cells or shared cells,…
over 6 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
I Need the book about Refrerence Guide for Administrators for OpenPlant
huayue
I Have a Book <PlantSpace Design Series Reference Guide for Administrators> I Need the book about Refrerence Guide for Administrators for OpenPlant Now How Can I get it.
Answered
over 6 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
what is the perfect plan for water plant design and Municipal water supply and drainage design ?
junjie shi
I just contact OPM soon, and i want to know what is the solution if i work on water plant design and Municipal water supply and drainage design? For example design,and rendering, and so on. what is the best combination of software?
over 6 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
Windows 10
gary Nichols
Does OPPID and OPM run under Win10 yet? Where do I find the readme files that has that in it? Thanks
Answered
over 6 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
Jacketed line isometric
Jayant Thakur
Is it possible to get the jacketed line isometric (showing jacket on main process line) in OPM?
over 6 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
How to get flow direction arrow on isometric in OPM?
Jayant Thakur
How can I get the flow direction arrow on isometric in OPM?
Answered
over 6 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
How can I generate single line BOP in OPM?
Jayant Thakur
Please suggest how can I generate BOP for a single line out of total project ? (If I have revised that particular line and need to generate grid report for that single line).
over 6 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
Calculated ECProperty adding two Double fields to be used in a dialog
Ray Lucas
HI All, Directional Pipe Guide, I currently have this support reading a spec to get the fields for the dialog box, it is all working. What I want to do now is to have a field in the spec CLEARANCE_GAP that is read as a new Property and then added…
Answered
over 6 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
Linking Elbows Supports to OpenPlant Physical Catalogue
Ray Lucas
Hi All, I've been modifying supports so they are spec driven in the schema, in most cases everything works. The only supports so far that I can't get to work are Elbow type supports - Adjustable Elbow Support, Dummy Leg Support. First are these…
over 6 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
Place a support on a TEE in OPM
Ray Lucas
Hi, How can you place a Stanchion Support on a TEE? We have a need to place supports on large pipe Tee's and can't find any support that will allow this. The work around is to place either notes and modify the Isometric or a add support on the pipe…
over 6 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
Report OPM Model Name on the Isometric OPIM
Ray Lucas
Hi, How can the OPM model name be shown on the OPIM Isometrics as an automatic field? This would need to be written out as part of the imodel and then linked to a TAG in the OPIM style, but I'm unsure how to do this.
over 6 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
How to show Tracing in OPM and OPIM
Ray Lucas
How can you show tracing on a Pipe in OPM and then have it show in OPIM? I can see how Insulation works, but I can't see tracing apart from a value under Operating Conditions of the Pipe Line in Pipeline Manager. I need the ability to specify the…
over 6 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
Adding the Pipe NOMINAL_DIAMETER to Support Location OPM
Ray Lucas
Hi All, I'm attempting to get the pipe/component diameter to automatically fill in the NOMINAL_DIAMETER of a Support Location. I see it is able to get the LINE_NUMBER and thought it could be done the same way, but I think it is not working as it is return…
over 6 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
Adding a new Vessel/Tank types to OpenPlant Modeler equipment list
Yurii Turko
Hello, Bentley team! I have a question about custom equipment in OpenPlant Modeler. How can I add a new equipment geometrical types( like cubic tanks) to already existing equipment in OpenPlant Modeler or even create a brand new custom equipment model…
over 7 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
OpenPlant Modeler & OpenPlant PID
Ihor Didyk
Hello, Bentley! I had been working with OpenPlant Modeler for couple of years. Obviously it's schema is quite customized due my working needs. Recently I've started to use OPPID and there is a lot of differences between schemas of programs, for example…
over 7 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
Create Level By Line Number
Shaun Raymond
Currently I place the piping components on a level corresponding to the service. ( How to Set Symbology of Pipeline by Service) Is it possible to automatically create levels by the line number and insert the pipe on that level instead? Thanks, …
Answered
over 7 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
RE: OpenPlant Modeler, Gaskets
Shaun Raymond
Problem Solved, found a Wiki on " How to Create a Custom Joint ".
over 7 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
How to Disable ProjectWise Desktop Integration with OpenPlant Modeler
Harpreet Singh
Applies To Product(s): OpenPlant Modeler Version(s): 08.11.09.XXX Environment: Windows 7 (64 bit) Area: ProjectWise Subarea: Original Author: Harpreet Singh, Bentley…
over 7 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki
RE: Yard Piping and Building Piping Matching up
Harpreet Singh
Hi Tyler, Could you please explain your workflow step by step? Mismatch happens after publishing I-model? Also confirm the OpenPlant version you are using. Regards, Harpreet
over 7 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
Yard Piping and Building Piping Matching up
Tyler White
Hi!! I have a big question and a bigger problem. We dont model our facilities at true position. All my piping was done in openplant. Yard piping takes our models and moves them to the correct coordinates. They then they pipe the yard and tie into our…
over 7 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
Open Plant Class Steam trap ?
Markus Wilbers
Hi all, i wanna integrate steam traps in my pipe class, but the schemas only have a Steam_trap class without any graphics information. Can i integrate steam traps myself, like i copy the left properties and information from another class (mybe from…
Answered
over 7 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum
How i can give Directional Support Guides attributinformation out of my Pipeclass
Markus Wilbers
Dear all, i wanna give the Directional Support Guides the Attributinformation out of my pipeclass. At the moment i get any random Attributinformation out of the system. i had try to add the custom property "OpenPlant_Physical_Catalogue_Class_Map…
Answered
over 7 years ago
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Forum