Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
  • Welcome
  • Products
  • Support
  • About
  • More
  • Cancel
OpenPlant | AutoPLANT
  • Product Communities
  • More
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki Bentley AutoPLANT and Navisworks
    • Sign in
    • -OpenPlant | AutoPLANT Wiki
      • +OpenPlant
      • -Bentley AutoPLANT
        • AutoPLANT Product Group Compatibility
        • +AutoPLANT Modeler CONNECT Edition
        • +AutoPLANT Modeler V8i
        • -AutoPLANT Piping
          • Advanced Routing in AutoPLANT Modeler
          • +AutoCAD - AutoPLANT Piping
          • +Component - AutoPLANT Piping
          • +Database - AutoPLANT Piping
          • -General - AutoPLANT Piping
            • ATDB0186. The current drawing is already registered in document register
            • ATDB0755 , ATDB0816, ATDB0817
            • AutoPLANT Issues with Navisworks
            • AutoPLANT Piping V8i SS3 64bit FAQ
            • AutoPLANT Piping V8i [FAQ]
            • AutoPLANT Piping [FAQ]
            • AutoPlant projects are not shown in root folders
            • AutoPLANT tool bars shows as ?
            • AutoPLANT V8i SELECT Series 1 08.11.06.30 Installation Check List And Installation Procedure [TN]
            • Bentley AutoPLANT and Navisworks
            • BPCom32Domain has stopped working
            • Database error ATDB0102: File copy procedure reported error number 2 attempting to replace the compressed database
            • How Do I Upgrade Projects From AutoPLANT XM To V8i [TN]
            • Installation Of The Latest Plant Security Manager For Pre-XM AutoPLANT Applications [TN]
            • Setting up environment variable in order to overcome a slow network condition
            • Steps to get the Center of Gravity out of a piping model
            • Where are AutoPLANT project and document DWG paths stored
            • “Unable to Load odbcji32.dll’ Error Message Appear Because of Windows Updates
          • How to Place Sloping Piping in AutoPLANT Modeler
          • +Open/Save - AutoPLANT Piping
          • +Processing - AutoPLANT Piping
          • +Reports - AutoPlant Piping
          • +Settings/Attributes - AutoPlant Piping
          • +Tools - AutoPlant Piping
        • +AutoPLANT Equipment
        • +AutoPLANT I&W
        • +AutoPLANT P&ID
        • +AutoPLANT Isometrics
        • +AutoPLANT AutoISOGEN
        • +Bentley Data Manager
        • +Vision/Document Manager
        • +Drawing Flattener
        • +DataSheets
        • +Specification Generator
        • +ProjectWise Integration
      • +Bentley Navigator
      • +Bentley PlantSpace
      • +Plant Project Tools
      • +Bentley Raceway and Cable Management
      • i-model Composition Service for S3D
      • Working from home with OpenPlant
      • Working from home with Bentley Raceway and Cable Management
      • Working from home with AutoPLANT Modeler
      • Your Feedback is important to us!

     
     Questions about this article, topic, or product? Click here. 

    Bentley AutoPLANT and Navisworks

    Applies To  Navisworks users who need to view AutoPLANT graphics
    Product(s): AutoPLANT Piping / Equipment / Modeler
    Version(s): 08.11.10.182
    Environment:  Windows 7 32 bit, Windows 7 64 bit, Windows XP 32, Windows XP 64
    Area:  General
    Subarea: 
    Original Author: Joey Bertone, Bentley Technical Support Group

    Autodesk Navisworks supports viewing Bentley AutoPLANT objects.  Autodesk Navisworks is not supported by Bentley however there are some commons issues that many AutoPLANT users encounter that can be corrected using the following solutions. If the follow does not correct the issues with Autodesk Navisworks please contact Autodesk technical support.

    Object enablers

    AutoPLANT object enablers are required to view AutoPLANT objects in Navisworks if AutoPLANT is not installed on the Navisworks may not be able to view the AutoPLANT objects.
    The AutoPLANT V8i object enablers can be downloaded by selecting on required version in this wiki:

    Objects show as wireframe

    If the AutoPLANT objects are visible but are showing as wireframe the shade mode must be changed from Automatic to shaded.

    Object enablers are installed but don't work

    Navisworks has an option to view DWG drawings using a file reader mode which opens the file as if it was an older version of AutoCAD. If a newer version of the AutoPLANT object enabler is installed and the file reader is set to read as an older version of AutoCAD Navisworks will not use the object enabler. Set the file reader version to a newer version of AutoCAD to use the object enabler.

    See Also

    Bentley Plant User Forum

    • GENERAL
    • Windows XP 32 bit
    • Windows 7 32 bit
    • Windows 7 64 bit
    • Windows XP 64 bit
    • Generic
    • 08.11.10.182
    • Navisworks
    • AutoPLANT Piping
    • SELECTsupport
    • Share
    • History
    • More
    • Cancel
    • Joey Created by Bentley Colleague Joey
    • When: Mon, Jan 13 2014 11:52 AM
    • Kestutis Mitkus Last revision by Bentley Colleague Kestutis Mitkus
    • When: Tue, Aug 7 2018 4:31 AM
    • Revisions: 16
    • Comments: 7
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2021 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies