In Auto PLANT, “Nozzle” can be place from piping module. If properties of piping nozzle to be available for OPIM, it needs to map these properties in the schema.
Ex: For default metric project, C:\ProgramData\Bentley\Plant V8i\BentleyPlantV8iProjects\SAMPLE_METRIC\Config\OpenPlant\schemas.
For “PropertyName” (highlighted above), Type “TAG” (which is the Auto PLANT property to which you want to map Equipment_tag).
This same procedure needs to follow for the “NUMBER” property (which we are going to map to the Auto PLANT “TAGNUMBER” property.
For “PropertyName” (highlighted above), Type “TAGNUMBER” (which is the Auto PLANT property to which you want to map Number).
The Auto PLANT “TAG” property is also mapped to another property in schema: “ORDER_NUMBER”. This appears to create a conflict. Because ORDER_NUMBER is not used in iso creation process, we need to remove TAG as data source for “ORDER_NUMBER”.
To show above schema changes in a connection label for the pipe nozzle user need to specify a user label in Open plant isometric configuration manager. See steps below: