Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
  • Welcome
  • Products
  • Support
  • About
  • More
  • Cancel
OpenPlant | AutoPLANT
  • Product Communities
  • More
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki Spec Validation Report Error: Some Properties in Spec Do Not Match in Component
    • Sign in
    • -OpenPlant | AutoPLANT Wiki
      • -OpenPlant
        • +CONNECT Services - OpenPlant
        • +Example Configuration - CONNECT Edition
        • +Installations - OpenPlant CONNECT Edition Applications
        • +OpenPlant Download Links & Videos
        • OpenPlant Product Compatibility
        • +OpenPlant Modeler CONNECT
        • +OpenPlant PID CONNECT
        • +OpenPlant Isometrics Manager CONNECT
        • +OpenPlant Orthographics Manager CONNECT
        • +OpenPlant Support Engineering CONNECT
        • +OpenPlant Project Administrator CONNECT
        • +OpenPlant CONNECT Edition-PlantSight Integration
        • -OpenPlant Modeler v8i
          • +Component - OpenPlant Modeler
          • +Drawing Generation- OpenPlant Modeler
          • -Errors, Logs, Messages, Crashes - OpenPlant Modeler
            • "Failed to Find Cell Library for Diagram" Error While Placing Equipment
            • "No Component Found With Initial Selection From Specs" Appears While Placing Component
            • Attach OpenPlant Modeler Objects in ProSteel
            • Deleting User Data Files Local and Roaming
            • Duplicate Key Tags Message in OpenPlant Modeler
            • Graphics Issue- Distorted graphics- Display Graphics in OpenPlant Modeler
            • How To Fix "Unable to Load Schema For StressApp" Error in OpenPlant Modeler
            • Invalid Catalog Selected Issues in OpenPlant Specification Generator
            • Invalid Joint Error while Validating Joint for Custom Components
            • Line 241 Error-Launching OpenPlant Modeler
            • Property is Read Only Error in OpenPlant Modeler
            • Selected Spec is Incompatible With the Current Project
            • -Spec Validation Report Error: Some Properties in Spec Do Not Match in Component
              • To Update Material, Schedule for Existing Model in OpenPlant Modeler
            • Standard Preferences Dialog Disappeared from OpenPlant Modeler
            • StartUp Error-Launching OpenPlant Modeler
            • Structural Synchronizer Engine Not Found Message when Selecting Repository from Structural tab
            • Tap Port Connection On Blind Flange Placement Issue
            • To Fix Incorrect Property Update while using AutoMatch Option
            • To Fix Joint Connection Error While Modeling Component
            • To Fix Missing Ports Information for PIPE_ELBOW_5_DEGREE in OpenPlant Modeler
            • To Fix Pro Steel Models Referenced in OpenPlant using Object Enabler
            • To Fix Support Rotation Issue By Manual Rotation or By placing supports using OpenPlant Support Engineering .
            • To Fix Unhandled Exception Error while Launching Pipeline Manager in OpenPlant Modeler V8i
            • To Fix Unhandled Exception Error “Index was outside the bounds of the array”
            • Too Many Results (XXXX).Select this to see items in details
            • Unable to Delete Corrupt Component in OpenPlant Modeler
            • Unable to Find Catalog Issue in OpenPlant Specification Generator
            • Wafer Joint on Components with Different Facing and Rating Shows Error While Placement
          • +Import/Export- OpenPlant Modeler
          • +Installation - OpenPlant Modeler
          • OpenPlant HVAC-OpenPlant Modeler
          • OpenPlant Modeler [FAQ]
          • +OpenPlant Specification Generator
          • +ProjectWise - OpenPlant Modeler
          • +Properties - OpenPlant Modeler
          • +Release Notes - OpenPlant Modeler
          • +Schema - OpenPlant Modeler
          • +Settings/Attributes - OpenPlant Modeler
          • +Structural Modeling Components (SMC)- OpenPlant Modeler
          • +Tasks - OpenPlant Modeler
          • +Training - OpenPlant Modeler
        • +OpenPlant Isometrics Manager v8i
        • +OpenPlant Project Administrator v8i
        • +OpenPlant PID v8i
        • +OpenPlant Orthographics Manager v8i
        • +OpenPlant Support Engineering v8i
        • +OpenPlant ModelServer v8i
        • +OpenPlant Reporting v8i
        • How to Connect with Bentley Technical Support Team using Microsoft Teams
        • How to Connect with Bentley Technical Support Team using Microsoft Teams via Browser
        • How to get list of installed applications/programs on Windows Machine using Command Prompt.
        • How to get list of Windows Updates installed on the machine using Command Prompt.
      • +Bentley AutoPLANT
      • +Bentley Navigator
      • +Bentley PlantSpace
      • +Plant Project Tools
      • +Bentley Raceway and Cable Management
      • i-model Composition Service for S3D
      • Working from home with OpenPlant
      • Working from home with Bentley Raceway and Cable Management
      • Working from home with AutoPLANT Modeler
      • Your Feedback is important to us!

     
     Questions about this article, topic, or product? Click here. 

    Spec Validation Report Error: Some Properties in Spec Do Not Match in Component

    Applies To 
    Product(s): OpenPlant Modeler
    Version(s): 08.11.09.XXX (SS5) 
    Environment:  Windows 7/8.1/10 (64 bit)
    Area:  -
    Subarea:  -
    Original Author: Rahul Kumar, Bentley product Advantage Group

    Overview

    During modeling, sometimes few attributes or properties may append as per requirement and spec gets revised time to time. Considering the case it is required to update existing component with revised information. In OpenPlant Modeler, specs can be validated through an option ‘Validation of Spec for components’ in pipeline Manager. To add new attribute/property in spec and to get it checked during spec validation process, below are the steps to follow. 

    Problem Description

    While Validating spec, newly added property report error 'Some Properties in Spec Do Not Match in Component'. See image below.

    To get it implemented, below steps will describe, adding a new property in Schemas, mapping its property to enable it to fetch the information from specs and display it on its attribute fields in OpenPlant Modeler. Adding the attribute to Configuration variable will get it checked during the time of spec validation. Below exercise has been created to explain it further.

    Steps to Resolve

    1. Launch OpenPlant Modeler, select Project OPModeler_Metric here.
    2. Create a Sample Piping Model with some fittings, say EQUAL_PIPE_TEE.
    3. Close OpenPlant Modeler.
    4. In class editor, open OpenPlant_CustomAttributes.08.11.ecschema.xml schema. This will enable to get the custom Attribute OpenPlant_Physical_Catalogue_Property_Map from it.
    5. Again open OpenPlant_3D.01.04.ecschema.xml schema.
    6. Supplement it with OpenPlant_3D_Supplemental_Modeling.01.04.ecschema.xml schema.
    7. Navigate to Piping Component class and create a property TEST_ATTRIBUTE.
    8. Add Custom Attribute OpenPlant_Physical_Catalogue_Property_Map to above property created. See image below.



    9. Open Configuration dialog box through Workspace option present in main menu and search for variable OPM_SPECVALIDATION_ATTRIBUTESTOCHECK. See image below. 



    10. Edit the variable and add new attribute TEST_ATTRIBUTE to enable a check during spec validation process. 



    11. Select OK and save settings.
    12. Launch OpenPlant Modeler, Open Pipeline Manager and do the spec Validation.
    13. Existing components and fittings will be reported as Inconsistent. See image below.



    14. Click on Update spec option. This will update the new attribute to existing components. 

    See Also

    Comments or Corrections?

    Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!

    • OpenPlant Modeler
    • Spec Validation Report Error
    • 08.11.09.XXX
    • Migrated_v8i-CE
    • Component
    • Share
    • History
    • More
    • Cancel
    • Rahul Kumar Created by Bentley Colleague Rahul Kumar
    • When: Fri, Sep 26 2014 9:12 AM
    • Aishwarya Kulkarni Last revision by Aishwarya Kulkarni
    • When: Thu, Dec 31 2020 3:03 PM
    • Revisions: 9
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2022 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies