Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
OpenPlant | AutoPLANT
  • Product Communities
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki Error[5]Cell not found in libraries: GATSW_FT
    • Sign In
    • -OpenPlant | AutoPLANT Wiki
      • -OpenPlant
        • +CONNECT Services - OpenPlant
        • +Example Configuration - CONNECT Edition
        • +Installations - OpenPlant CONNECT Edition Applications
        • +OpenPlant Download Links & Videos
        • OpenPlant Product Compatibility
        • +OpenPlant Modeler CONNECT
        • +OpenPlant PID CONNECT
        • +OpenPlant Isometrics Manager CONNECT
        • +OpenPlant Orthographics Manager CONNECT
        • +OpenPlant Support Engineering CONNECT
        • +OpenPlant Project Administrator CONNECT
        • +OpenPlant CONNECT Edition-PlantSight Integration
        • +OpenPlant Modeler v8i
        • -OpenPlant Isometrics Manager v8i
          • +OpenPlant Isometrics Manager for OpenPlant
          • -OpenPlant Isometrics Manager for AutoPLANT
            • Installation/Upgradation Steps of OpenPlant Isometrics Manager for AutoPLANT
            • -Errors, Logs, Messages, Crashes - OpenPlant Isometrics Manager for AutoPLANT
              • Description for Bolts, Gaskets In Isometric BOM Showing as "NODESC"
              • Element ‘VALVE_HAS_VALVE_OPERATING _DEVICE’ is missing required attribute ‘sourceClass’
              • Error: Mapping of component not found, Class Name: BASE_AT_LUG_W_BOLT
              • Error: Mapping of component not found, Class Name: AT_PVIC_AT_SOCKETWELD
              • Error: The Process cannot Access the File in OpenPlant Isometrics Manager
              • Error: Scaler, Symbols or Item code are missing for TAP_CONNECTION when Branch Connected Through Stub-In Tapport
              • Error: XCHG0000: Failed to initialize OpenPlant Isometric data converter 1
              • Error: XCHG0000: Invalid Translation Format: OPIM in OpenPlant Isometrics Manager
              • Error[0]: Unable to locate ADDON (ID=XXX) to DCP
              • Error[0]: Unable to Locate ADDON (4) to DCP when Miscellaneous Attachment on Pipe
              • Error[5]Cell not found in libraries: GATSW_FT
              • Error[5] Unable to Place Symbol: FLNWNF, PGKT, GATFL When Use Custom Seed File (Backing Sheet)
              • ERROR[5]: DWG creation failed while Generating Isometric Output as DWG Format
              • To Avoid Crash for End Types WFL & Butt Weld Connections in Isometrics
              • Isometric successfully, but PCF generation failed Message in OpenPlant Isometrics Manager
              • Unresolved References Files Error on Opening DWG Isometric in AutoCAD
              • Check Internet Connection and Restart the Setup or Provide Proxy Settings
              • References-Unresolved Reference file error while opening DWG format Isometric drawing in AutoCAD
              • The Specified module could not be found (Exception from HRESULT: 0X8007007E)
            • +Open/Save - OpenPlant Isometrics Manager for AutoPLANT
            • +Processing - OpenPlant Isometrics Manager for AutoPLANT
            • +Settings/Attributes - OpenPlant Isometrics Manager for AutoPLANT
            • How to Change Miscellaneous Attachment Annotation Container in CONNECT Edition
            • How to Change Text Font, Size, Color and Location in BOM Using Text Nodes in CONNECT Edition
            • How to Create Special Stamps using Detail Sketches in OpenPlant Isometrics Manager in CONNECT Edition
            • How to Create Special Stamps using Reports in OpenPlant Isometrics Manager in CONNECT Edition
            • How to Delete Ecxml Files, after certain Period in CONNECT Edition
            • How to Export Bill of Material In CSV Excel Format for AutoPLANT Modeler in CONNECT Edition
            • How to Publish Isometrics in DGN, DWG and PDF Output Formats in CONNECT Edition
            • How to Save Isometrics Output on Network Drive for AutoPLANT in CONNECT Edition
          • +Release Notes - OpenPlant Isometrics Manager
          • OpenPlant Isometrics Manager [FAQ]
        • +OpenPlant Project Administrator v8i
        • +OpenPlant PID v8i
        • +OpenPlant Orthographics Manager v8i
        • +OpenPlant Support Engineering v8i
        • +OpenPlant ModelServer v8i
        • +OpenPlant Reporting v8i
        • How to Connect with Bentley Technical Support Team using Microsoft Teams
        • How to Connect with Bentley Technical Support Team using Microsoft Teams via Browser
        • How to get list of installed applications/programs on Windows Machine using Command Prompt.
        • How to get list of Windows Updates installed on the machine using Command Prompt.
        • How to Package WorkSpace to be Shareable to Users for OpenPlant Projects
        • How to find iModel.dgn file of another domain in PlantSight
      • +Bentley AutoPLANT
      • +Bentley Navigator
      • +Bentley PlantSpace
      • +Plant Project Tools
      • +Bentley Raceway and Cable Management
      • i-model Composition Service for S3D
      • Working from home with OpenPlant
      • Working from home with Bentley Raceway and Cable Management
      • Working from home with AutoPLANT Modeler
      • Your Feedback is important to us!

     
     Questions about this article, topic, or product? Click here. 

    Error[5]Cell not found in libraries: GATSW_FT

    Applies To
    Product(s): OpenPlant Isometrics Manager
    Version(s): 08.11.09.XXX
    Environment: Windows 7 (64 bit)
    Area: Settings/Attributes
    Subarea:
    Original Author: Rahul Kumar, Bentley Product Advantage Group

    Overview

    During isometrics generation in OpenPlant Isometrics Manager, mentioned error coming due to missing cell file is most common.To avoid this, user need to add the types in cell template file present in Isometrics folder.

    Problem Description

    Error produced during isometrics generation with AutoPLANT Modeler is most common with this end type detail. However with OpenPlant modeler there might be certain types where such issue occurs. The message displays as ‘Error[5]Cell not found in libraries: GATSW_FT’. Below are the steps to fix this issue.

    Steps to Resolve

    1. Launch OpenPlant isometrics Manager. Click on Configuration button.

    2. From ‘Advance’ node select ‘Open Seed File’ option. See image below. 



    3. From Main Menu, go to "IsoExtractor"> "Cell Creation Tool".

    4. Click on "Open Template File" Option and select "Valves" DGN file and click on "Open". See image below.



      Note - OpenPlant Isometrics Manager is delivered with template files for use when creating new cells. The template files are located in the …\OPIM\Cell Templates folder of the OpenPlant Isometrics Manager workspace.

    5. Check the existing End type connections and Copy it under the same table.



      Note- It is good practice to make a backup of the template file before making changes.

    6. For type GATSW_FT, modify the end types for SW(Socket Weld) and FT (Female Threaded). Rename the Description and cell name as GATSW_FT. Also modify the end connection for FT. See image below. 



    7. With modified symbol in table, ensure correct connection point and Fence it from task bar. Also define the changes in custom.cel file, See below images for few customization:



      Note - It is good practice to save the new symbol to Custom.cel to differentiate it from default file.

    8. Save settings and close the seed file.

    9. Generate Isometrics and verify results.

    See Also
    Modifying Symbols in OpenPlant Isometrics Manager
    Applies To Product(s): OpenPlant Isometrics Manager Version(s): 08.11.09.XXX(SS5) | 08.11.11.XXX(SS6) Environment: Windows 7/8.1/10 (64 bit) Area: Settings/Attributes…
    Last edited over 4 years ago in OpenPlant | AutoPLANT > OpenPlant | AutoPLANT Wiki
    2 comments

    Comments or Corrections?

    Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!

    • apm
    • Cell
    • AutoPLANT Modeler
    • OPIM
    • 08.11.09.404
    • 08.11.09.XXX
    • Library
    • template
    • OpenPlant Isometrics Manager
    • GATSW
    • Share
    • History
    • More
    • Cancel
    • Rahul Kumar Created by Bentley Colleague Rahul Kumar
    • When: Tue, Oct 7 2014 10:24 AM
    • Kestutis Mitkus Last revision by Bentley Colleague Kestutis Mitkus
    • When: Thu, Dec 13 2018 6:22 AM
    • Revisions: 10
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies