How To Set Reducer Size Annotation in BOM Report


 
 Applies To 
  
 Product(s): OpenPlant Isometrics Manager
 Version(s):08.11.09.404
 Environment: Windows 7 (64 bit)
 Area: Settings/Attributes
 Subarea: 
 Original Author:Rahul Kumar, Bentley Product Advantage Group
  

To set size annotation for Reducers, in BOM report for OpenPlant Isometrics Manager. 

Background

During Isometrics drawing generation process, both OpenPlant Modeler/AutoPlant Modeler, dimension for reducers shown differently as "SIZE1" and "SIZE2'. Sometimes user requirement is to show both dimension with ‘X’ cross marks. It will give an easier presentation in reading reports for fittings. Below steps will help user to achieve it.

Steps to Accomplish

  1. Launch OpenPlant Isometrics Manager.

  2. Click on Configuration button to launch Isometric configuration dialog box. 



  3. From Advanced option, click on "Open report Definition". See image below.



    Note: Report.def file can also be opened through navigating project root folder. See below.
    C:\ProgramData\Bentley\%Project Root%\Isometrics\Styles\IFC\Config

  4. Add a row to under shop report as mentioned below.
    COLUMN =  7: R : SIZE   

  5. Save and close report.

  6. Generate Isometrics and verify result. See image below.

See Also

Configuring the BOM and Reports-communities.bentley.com/.../12642.configuring-the-bom-and-reports

Comments or Corrections?

Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!