You are currently reviewing an older revision of this page.
To set size annotation for Reducers, in BOM report for OpenPlant Isometrics Manager.
During Isometrics drawing generation process, both OpenPlant Modeler/AutoPlant Modeler, dimension for reducers shown differently as 'SIZE1' and 'SIZE2'. Sometimes user requirement is to show both dimension with ‘X’ cross marks. It will give an easier presentation in reading reports for fittings. Below steps will help user to achieve it.
Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!