Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
OpenPlant | AutoPLANT
  • Product Communities
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki How to Identify Inconsistency of Component Data with Consistency Checker
    • Sign In
    • -OpenPlant | AutoPLANT Wiki
      • -OpenPlant
        • +CONNECT Services - OpenPlant
        • +Example Configuration - CONNECT Edition
        • +Installations - OpenPlant CONNECT Edition Applications
        • +OpenPlant Download Links & Videos
        • OpenPlant Product Compatibility
        • +OpenPlant Modeler CONNECT
        • +OpenPlant PID CONNECT
        • +OpenPlant Isometrics Manager CONNECT
        • +OpenPlant Orthographics Manager CONNECT
        • +OpenPlant Support Engineering CONNECT
        • +OpenPlant Project Administrator CONNECT
        • +OpenPlant CONNECT Edition-PlantSight Integration
        • -OpenPlant Modeler v8i
          • +Component - OpenPlant Modeler
          • +Drawing Generation- OpenPlant Modeler
          • +Errors, Logs, Messages, Crashes - OpenPlant Modeler
          • +Import/Export- OpenPlant Modeler
          • +Installation - OpenPlant Modeler
          • OpenPlant HVAC-OpenPlant Modeler
          • OpenPlant Modeler [FAQ]
          • +OpenPlant Specification Generator
          • +ProjectWise - OpenPlant Modeler
          • -Properties - OpenPlant Modeler
            • +Fundamentals of External Database Query in OpenPlant Modeler
            • How to Add Component's Facing Property in Element Information dialog
            • How to Add Inch Sign with Nominal Diameter in Pipeline Tag
            • How to Add New/Existing Property to Nozzle Manager Dialog in OpenPlant Modeler
            • How to Add/Remove Properties in Flyover Hints
            • How to Associate the Specification Based on Service
            • How To Change Attributes of Pipe Based on Component State Using Named Expression
            • How to Change the Units of Measurement for ECProperty in OPM
            • How To Create and Populate Service Description Property on Piping Component Element Information
            • How to Exclude Plant Area Property From Consistency Checker
            • How to get Joint Type Information on Gaskets
            • How to Identify Inconsistency of Component Data with Consistency Checker
            • How to Map Spec Field with OpenPlant Modeler Property
            • How to Modify Supports in Bulk in OpenPlant Modeler
            • How to Move Properties Between Categories
            • How to Populate Header Nominal Diameter for Tap Connection in OpenPlant Modeler
            • How to Prefix 'DN' with Pipe Size in OPM
            • How to Set Default Value on EC Property
            • How to Show Nominal Diameter in Three-Digit Format for Support Tag Name
            • How to Update Bolts and Gaskets in OpenPlant Modeler
            • How to Update Pipeline Tag Name or Component Property After any Changes in Schema
            • To Modify Equipment Tag For FreeForm Nozzle in OpenPlant Modeler
            • To Modify Pipeline Tag Name in OpenPlant Modeler
            • To Obtain Arc Length for Pipe Bends in OpenPlant Modeler
          • +Release Notes - OpenPlant Modeler
          • +Schema - OpenPlant Modeler
          • +Settings/Attributes - OpenPlant Modeler
          • +Structural Modeling Components (SMC)- OpenPlant Modeler
          • +Tasks - OpenPlant Modeler
          • +Training - OpenPlant Modeler
        • +OpenPlant Isometrics Manager v8i
        • +OpenPlant Project Administrator v8i
        • +OpenPlant PID v8i
        • +OpenPlant Orthographics Manager v8i
        • +OpenPlant Support Engineering v8i
        • +OpenPlant ModelServer v8i
        • +OpenPlant Reporting v8i
        • How to Connect with Bentley Technical Support Team using Microsoft Teams
        • How to Connect with Bentley Technical Support Team using Microsoft Teams via Browser
        • How to get list of installed applications/programs on Windows Machine using Command Prompt.
        • How to get list of Windows Updates installed on the machine using Command Prompt.
        • How to Package WorkSpace to be Shareable to Users for OpenPlant Projects
        • How to find iModel.dgn file of another domain in PlantSight
      • +Bentley AutoPLANT
      • +Bentley Navigator
      • +Bentley PlantSpace
      • +Plant Project Tools
      • +Bentley Raceway and Cable Management
      • i-model Composition Service for S3D
      • Working from home with OpenPlant
      • Working from home with Bentley Raceway and Cable Management
      • Working from home with AutoPLANT Modeler
      • Your Feedback is important to us!

     
     Questions about this article, topic, or product? Click here. 

    How to Identify Inconsistency of Component Data with Consistency Checker

    Applies To
    Product(s): OpenPlant Modeler
    Version(s): 08.11.09.XXX (SS5) & 08.11.11.xx (SS6)
    Environment: Windows 7 (64 bit)
    Area: Component
    Subarea: Data
    Original Author: Harpreet Singh, Bentley Product Advantage Group

    Background

    While working on 2D/3D consistency checker issue, there is a warning sign on the pipeline node which indicates the inconsistency in component data even though the properties match.

               

    Steps to Accomplish

    This issue occurs mostly when a component is placed from the component task bars rather than from the consistency checker itself. To Identify the cause follow the steps below.

    1. Go to Utilities> Key-In Command and apply key-in command "mechaddinccreport".



    2. In the Consistency checker report dialog box, give the file name to save the report and click Generate Report.



    3. In the report viewer dialog, expand Modified Instances node and then expand MAJOR_PIPELINE node. Select pipeline to check the inconsistency.



    4. As shown in the above picture the inconsistency is due to the mismatch of GUID. When we create pipeline from Consistency Checker tree GUID will be inherited from 2D data coming from an I-model whereas if the same pipeline is created within OpenPlant Modeler, a new GUID is assigned to it which causes the mismatch.

    5. If you do not wish to include the GUID for consistency check, you can turn it off by following the steps below
      1. Launch Class editor and load OpenPlant_Supplemental_ConsistencyChecker schema.
      2. On BENTLEY_BASE_OBJECT class, select GUID property.
      3. Set "IsSharedProperty" to FALSE and save the schema.



      4. The above change will ignore the GUID property when using consistency checker in OpenPlant Modeler.

    See Also

    http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/29758.how-to-exclude-a-property-from-consistency-checker 

    Comments or Corrections?

    Bentley's Product Advantage Group requests that you please confine any comments you have on this Wiki entry to this "Comments or Corrections?" section. THANK YOU!

    • 08.11.11.xxx
    • OpenPlant Modeler
    • OPM
    • 08.11.09.XXX
    • inconsistency
    • 2D-3D
    • GUID
    • Consistency Checker
    • Share
    • History
    • More
    • Cancel
    • Harpreet Singh Created by Harpreet Singh
    • When: Tue, Oct 21 2014 10:18 AM
    • Rahul Kumar Last revision by Bentley Colleague Rahul Kumar
    • When: Mon, Aug 22 2016 8:44 AM
    • Revisions: 4
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies