You are currently reviewing an older revision of this page.
For OpenPlant Isometrics Manager Weld report can be generated using Report.def file present in Config folder located in its project root. It can be experienced using both OpenPlant modeler and AutoPlant.
While creating weld report through report.def file to show weld tags, they were not coming in numerical order. The weld order varied from line to line. See image below for reference. The weld tags need to be displayed in numerical order right from Top to Down. Below are the steps to achieve it in a correct way.
Numerical order
#-----------------------------------------------------------------------------REPORT = WELD EXCLUDE = IE_TYPE=CT_PIPE|CT_BEND|CT_BOLT|.*VALVE.*|CT_FLANGE|CT_ELBOW|CT_GASKET|CT_.*FITTING.*|CT_SUPPORT|CT_REDUCER|CT_OLET COLUMN = 6:C:WELDID COLUMN = 80:W:IE_DESCRIPT SORT = WELDID:N NODE = 61
END
Sequencing order
http://communities.bentley.com/products/plant/design___engineering/w/plant_design_and_engineering__wiki/12642.configuring-the-bom-and-reports
Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!