To skip the labels on Flange Assemblies in Isometrics Drawing.
In OpenPlant Isometrics Manager, on flanged assemblies mating component do possess seals and fasteners which labels altogether like Fx Gy Bz. In some cases requirement is to display only flange index. By using the ‘SKIP’ variable, modeler can disable the other labels on isometric drawing. Below steps illustrates on modifying the rep_sortgroups.tx file.Below explanation has been illustrated in context with OpenPlant Modeler & OpenPlant Isometrics Manager.
To Delete the Gasket & Fastener from BOM report -
Add expression in report.def file as shown in below image:
To Show Gaskets & Bolts in Bill Of Material separately -
Note: Using the Above two modification in report.def file will provided flexibility to user to customize the BOM irrespective of Labels in drawings.
See results below:
You may also refer OpenPlant Isometrics Manager help file menu for Explore Style Configuration option.