Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
  • Welcome
  • Products
  • Support
  • About
  • More
  • Cancel
AutoPLANT | OpenPlant | PlantWise
  • Product Communities
  • More
AutoPLANT | OpenPlant | PlantWise
AutoPLANT | OpenPlant | PlantWise Wiki 'Locate Missing Reference Schema Files' message while loading Schema in Class Editor
    • Sign in
    • -AutoPLANT | Bentley Raceway and Cable Management | OpenPlant | PlantWise Wiki
      • -OpenPlant
        • +CONNECT Services - OpenPlant
        • +Example Configuration - CONNECT Edition
        • +Installations - OpenPlant CONNECT Edition Applications
        • +OpenPlant Download Links & Videos
        • OpenPlant Product Compatibility
        • +OpenPlant Modeler CONNECT
        • +OpenPlant PID CONNECT
        • +OpenPlant Isometrics Manager CONNECT
        • +OpenPlant Orthographics Manager CONNECT
        • +OpenPlant Support Engineering CONNECT
        • +OpenPlant Project Administrator CONNECT
        • +OpenPlant CONNECT Edition-PlantSight Integration
        • +OpenPlant Modeler v8i
        • +OpenPlant Isometrics Manager v8i
        • +OpenPlant Project Administrator v8i
        • -OpenPlant PID v8i
          • +Application Solutions - OPPID
          • -Class Editor - OpenPlant PID
            • 'Locate Missing Reference Schema Files' message while loading Schema in Class Editor
            • ECExpressions explained - Calculated ECProperty
            • How to Get Line Tag info For Pressure Reducing Valve
            • How to Modify/Add Validation State to Components in OpenPlant PID
            • How to Reference a Schema into Primary Schema
          • +Customization - OpenPlant PID
          • +Database - Plant Project
          • +Properties - OpenPlant PID
          • +Release Notes - OpenPlant PID
          • +Training - OpenPlant PID
          • +White Papers/Guidelines - OPPID
        • +OpenPlant Orthographics Manager v8i
        • +OpenPlant Support Engineering v8i
        • +OpenPlant ModelServer v8i
        • +OpenPlant Reporting v8i
        • How to Connect with Bentley Technical Support Team using Microsoft Teams
        • How to Connect with Bentley Technical Support Team using Microsoft Teams via Browser
      • +Bentley AutoPLANT
      • +Bentley Navigator
      • +Bentley PlantSpace
      • +Plant Project Tools
      • +Bentley Raceway and Cable Management
      • i-model Composition Service for S3D
      • Working from home with OpenPlant
      • Working from home with Bentley Raceway and Cable Management
      • Working from home with AutoPLANT Modeler
    • How to Associate the Specification Based on Service in OpenPlant Modeler Connect

     
     Questions about this article, topic, or product? Click here. 

    'Locate Missing Reference Schema Files' message while loading Schema in Class Editor

    Applies To 
    Product(s): OpenPlant PID
    Version(s): 08.11.10.XXX (SS5) | 08.11.11.XXX (SS6)
    Environment:  Windows 7/8.1/10 (64 bit)
    Area:  Class Editor
    Subarea: 
    Original Author: Harpreet Singh, Bentley Product Advantage Group

    Problem Description

    When we load OpenPlant_PID schema or supplement the schema, class editor asks to locate a missing reference file and shows below file open dialog:

    Basically when any project/workspace schema is loaded in class editor it references in various schemas but when the location of reference schema is not found then it shows the above dialog.

    Steps to Resolve

    You need to add the location of these schemas in class editor once and it will automatically reference in the schemas from the next time and won't ask for the location. Follow the steps below to resolve the issue:

    1. Open Class Editor.

    2. Go to Tools>Options, a dialog will open.



    3. Click on Add button and browse to the below paths:

      Installation Folder Schemas : C:\Program Files (x86)\Bentley\PowerPID (SELECTseries 5)\PowerPID\schemas

      Workspace Schemas: C:\ProgramData\Bentley\PowerPID (SELECTseries 5)\WorkSpace\OPPowerPID\schemas



    4. Once the paths are added, click Apply button and close the dialog. Now when you load the schemas, the schema files will get referenced in automatically.

    See Video

    Comments or Corrections?

    Bentley's Product advantage Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU! 

    • Class Editor
    • schema
    • Locate Missing Reference Schema
    • ECSchema
    • Share
    • History
    • More
    • Cancel
    • Harpreet Singh Created by Bentley Colleague Harpreet Singh
    • When: Wed, Mar 11 2015 9:11 AM
    • Jaya Tiwari Last revision by Jaya Tiwari
    • When: Wed, Oct 24 2018 4:15 AM
    • Revisions: 4
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2021 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies