Bentley Communities
Bentley Communities
  • Site
  • User
  • Site
  • Search
  • User
OpenPlant | AutoPLANT
  • Product Communities
OpenPlant | AutoPLANT
OpenPlant | AutoPLANT Wiki How to Customize Equipment Annotation
    • Sign In
    • -OpenPlant | AutoPLANT Wiki
      • -OpenPlant
        • +CONNECT Services - OpenPlant
        • +Example Configuration - CONNECT Edition
        • +Installations - OpenPlant CONNECT Edition Applications
        • +OpenPlant Download Links & Videos
        • OpenPlant Product Compatibility
        • +OpenPlant Modeler CONNECT
        • +OpenPlant PID CONNECT
        • +OpenPlant Isometrics Manager CONNECT
        • +OpenPlant Orthographics Manager CONNECT
        • +OpenPlant Support Engineering CONNECT
        • +OpenPlant Project Administrator CONNECT
        • +OpenPlant CONNECT Edition-PlantSight Integration
        • +OpenPlant Modeler v8i
        • +OpenPlant Isometrics Manager v8i
        • +OpenPlant Project Administrator v8i
        • -OpenPlant PID v8i
          • +Application Solutions - OPPID
          • +Class Editor - OpenPlant PID
          • -Customization - OpenPlant PID
            • -Customize Tag or Annotation
              • Customize Pipeline Annotation to Include Service & Insulation Properties
              • Default Annotation of Pipe Run with Pipeline Tag in OpenPlant PID
              • How to Add 'DN' Prefix to Valve Size Annotation in OpenPlant PID
              • How to Add Bubble Location For Flow Meter in OpenPlant PID
              • How To Add Custom Property in Pipeline Tag in OpenPlant PID
              • How to Add PIPELINE_NUMBER in Valve Tag in OpenPlant PID
              • How to Add Properties to Flow Flag Annotation in KKS Project
              • How to Assign Temporary Tag to Equipment and Map it With Database Field
              • How to Associate Pipeline Tag Number with Valve
              • How to Automatically Annotate Nozzle Tag After Placement
              • How to Change Annotation Text Color in OpenPlant PID
              • How to Change the TAG_TYPE of Components in OpenPlant PID
              • How to Configure the Location of Annotations in Instrument Bubble
              • How to Create Custom Tag Type and Map it to Existing Class in OPPID
              • How to Customize Equipment Annotation
              • How to Customize Motor Tag Format in OpenPlant PID
              • How to Customize Pipeline Box Annotation
              • How to define color for Manual Annotation same as Default Annotation
              • How to Display Valve Annotation in Two Rows
              • How to Enable Fitting Components as Tagged Component.
              • How to Fix Reducer Annotation to Always Show Larger Diameter First
              • How to Have Strainers Tag With a Bubble like Control Valves
              • How To Have Valve Annotations Show Up in Specific Level
              • How to Include Area & Unit Property In Instrument Bubble Annotation
              • How to Include Size & Area Property in Pipeline Tag
              • How to make frame on label fit for support tags.
              • How to Modify the Text Style of Pipeline Annotations
              • To Avoid Pipeline Annotation While Placing Off Page Connector Connected to Already Placed Pipeline in OpenPlant PID
            • +How do Modify the Component Flow Arrow?
            • How To Add & Write New Pipeline Size in OpenPlant PID
            • How to Add Custom Border in OpenPlant PID
            • How to Add Unit Abbreviations in DGN Reports and in the Databse
            • How to Add Units of Measurement on Property in OpenPlant PID
            • How to add “DN” prefix to valve size annotation in OpenPlant PID CONNECT Edition.
            • How to Add/Remove Tools in Main Task of OpenPlant PID
            • How to Assign Color by Service to the Pipeline
            • How to Assign Color to Equipment, Nozzle & Instrument by Service.
            • How to Break Multiple Properties on Spec Break
            • How to by pass the default line break and have a pipeline place on top of equipment.
            • How to Calculate and Customize the PID Text Style Size for Components
            • How to Change Pipeline Color and Line Weight in OpenPlant PID
            • How to change the Date format for properties in OpenPlant PID CONNECT Edition.
            • How to Change the Order of Properties in Element Info and Component Dialog
            • How to Change the Priority of Pipe run Breaks
            • How to Configure OpenPlant PID to Show Imperial & Metric sizes in the Same Project
            • How To Create a Capsule Symbol for Instrument Winterization
            • How to create a pick list on EC Property using External Datasource definition
            • How to Create Battery Limit Symbol with Mirroring Capability in OpenPlant PID
            • How to Create Custom Icon in OPPID
            • How to Create Custom Instrument and Custom Property Annotation.
            • How to Create Custom Spec Break with Extended Leader Line in OpenPlant PID
            • How to create Custom Valve Tag annotation which contains Custom Property that has a Drop-down option
            • How to Create Drop Down list on EC Property in OpenPlant PID
            • How to Create Multi-line Style Pipeline with Different Line Weights
            • How to customize Border Attribute Fonts?
            • How to Format number property on Equipment and Pipelines in OpenPlant PID
            • How to get Association Property of One Project to Another Project
            • How to Get Drop Down List in Number Property of Instrument
            • How to get Line Tag Info for PRV in Data Manager
            • How to Hide Unused Properties on EC Class
            • How to Implement a Secondary Instrument Database Table
            • How to Make a Valve Replaceable in OpenPlant PID
            • How to Make Off-Page Connector Rotatable to Place in Vertical Direction
            • How to make Page Connector Orientable
            • How to Make Pressure Reducing Valve Orient to Bigger Size
            • How to Make Revision Property Allow Alpha-Numeric Characters
            • How to Mirror or Rotate a Custom Equipment or Component while Placement
            • How to Modify Default Value for Device Type Code to a Specific Component Class
            • How to modify Specialty item
            • How to place pipeline Tag to pipe run automatically in OpenPlant PID CONNECT Edition.
            • How to Populate Component Class Name in Element information for OpenPlant PID
            • How to Propagate Property Value From Pipe Run to Pipeline to Update Pipeline Tag and Annotation
            • How to Pull Properties from Pipe Run to Annotate on Off-Page Connectors
            • How to Resize the Control Valve Actuators in OpenPlant PID
            • How to Set Any Component to Repeat the Insertion After Placement
            • How to Set Same Level to Major & Minor Pipeline but Different Line weight
            • How to Turn of PID Document Settings Dialog at OpenPlant PID Starting
            • How To Use Page Connectors to Show Information Between Two DGNs
            • Open Plant PID Grid and lock settings
            • OPPID: How do I Add a Custom Logo to a Border?
            • Placing Custom Component Leaves Gap in Component and Pipe Run
            • To Exclude Pipe Run using Line List in Data Manager for OPPID
          • +Database - Plant Project
          • How to Cascade Associated Item's Value from Associated Class to Fitting Class in OpenPlant PID V8i
          • How to cascade Associated Items value from Pipeline to Reducer using Notifier in OpenPlant PID V8i
          • How to Change the Existing Cell Component Graphics in OpenPlant PID V8i
          • How to Fix Modified Tag Value Upon Second Sync in OpenPlant PID V8i
          • How to Hide the Actuator Prompt for Control Valve in OpenPlant PID V8i
          • How to include custom schema in OpenPlant PID under component manager
          • How to Point Custom WorkSpace Location in OpenPlant PID SS10
          • How to set the Fail Mode List for control valve Placement in OpenPlant PID V8i
          • +Properties - OpenPlant PID
          • +Release Notes - OpenPlant PID
          • +Training - OpenPlant PID
          • +White Papers/Guidelines - OPPID
        • +OpenPlant Orthographics Manager v8i
        • +OpenPlant Support Engineering v8i
        • +OpenPlant ModelServer v8i
        • +OpenPlant Reporting v8i
        • How to Connect with Bentley Technical Support Team using Microsoft Teams
        • How to Connect with Bentley Technical Support Team using Microsoft Teams via Browser
        • How to get list of installed applications/programs on Windows Machine using Command Prompt.
        • How to get list of Windows Updates installed on the machine using Command Prompt.
        • How to Package WorkSpace to be Shareable to Users for OpenPlant Projects
        • How to find iModel.dgn file of another domain in PlantSight
      • +Bentley AutoPLANT
      • +Bentley Navigator
      • +Bentley PlantSpace
      • +Plant Project Tools
      • +Bentley Raceway and Cable Management
      • i-model Composition Service for S3D
      • Working from home with OpenPlant
      • Working from home with Bentley Raceway and Cable Management
      • Working from home with AutoPLANT Modeler
      • Your Feedback is important to us!
    • Learning Content for OpenPlant

     
     Questions about this article, topic, or product? Click here. 

    How to Customize Equipment Annotation

    Applies To 
    Product(s): OpenPlant PID
    Version(s): 08.11.10.XXX
    Environment:  Windows 7 64 bit
    Area:  Customization
    Subarea: 
    Original Author: Harpreet Singh, Bentley Technical Support Group

    Description

    This article will explain how user can add their custom properties in the default equipment annotation and annotate it on the drawing.

    Steps to Accomplish

    1. Open class editor and load OpenPlant_PID schema supplemented with OpenPlant_PID_Supplemental_Imperial schema.
    2. Go to EQUIPMENT_ANNOTATION_ALT3 class.
    3. Add the custom property on this class. In this case DESCRIPTION2 property is added for example.



      Note: Add the Property Custom Attribute and add the default value as shown above. This step is critical.
    4. On the same class, locate TEXT property and replace MODEL with DESCRIPTION2 as shown below.

    5. Now save the changes in schema.

    Verify the Result

    1. Launch OPPID and open a drawing.
    2. Place an equipment and key-in the values for Description & Description2 properties.
    3. Select the annotation which we just modified.

    4. Hover the annotation over equipment and place it below the equipment.

    Comments or Corrections?

    Bentley's Technical Support Group requests that you please confine any comments you have on this Wiki entry to this Comments or Corrections?" section. THANK YOU!

    • 08.11.10.523
    • Equipment Annotation
    • Customization
    • OpenPlant_PID
    • Share
    • History
    • More
    • Cancel
    • Harpreet Singh Created by Harpreet Singh
    • When: Wed, Apr 8 2015 8:09 AM
    • Kestutis Mitkus Last revision by Bentley Colleague Kestutis Mitkus
    • When: Mon, Mar 5 2018 3:56 AM
    • Revisions: 2
    • Comments: 0
    Recommended
    Related
    Communities
    • Home
    • Getting Started
    • Community Central
    • Products
    • Support
    • Secure File Upload
    • Feedback
    Support and Services
    • Home
    • Product Support
    • Downloads
    • Subscription Services Portal
    Training and Learning
    • Home
    • About Bentley Institute
    • My Learning History
    • Reference Books
    Social Media
    •    LinkedIn
    •    Facebook
    •    Twitter
    •    YouTube
    •    RSS Feed
    •    Email

    © 2023 Bentley Systems, Incorporated  |  Contact Us  |  Privacy |  Terms of Use  |  Cookies