When we have setup the OpenPlant ModelServer repository in Projectwise and when open any file, by default it connects to the repository. This article will explain how the default connection with OPMS can be disabled with various options.
There is a configuration variable in opms.cfg file in C:\Program Files (x86)\Bentley\OpenPlantModeler V8i\OpenPlantModeler\config\appl folder which helps in disabling the default connection with OPMS reporsitory.
OPMS_DEFAULT_CONNECTION_MODE, By default it's value is 1 which means default connection mode.
By default when you open a model in standalone mode, you see dialog to connect to the repository. But if you don't want to connect to the repository then you can use the same configuration variable to disable the dialog box.