Background
How to show Miscellaneous Attachment (Test Port Instrument Bubble) with tag number in isometric.
Steps to Accomplish
1. Open class editor and navigate to project path and open schema- OpenPlant_3D.01.04.ecschema.xml. For ex. C:\ProgramData\Bentley\Plant V8i\Bentley Plant V8i Projects\SAMPLE_METRIC\Config\OpenPlant\schemas.
2. Supplement schema- OpenPlant_3D_Supplemental_Isometrics_Isoextractor.01.04.ecschema.xml
3. Now, search "Note” class found under Plant base object>Named Item.
4. Under note class create new class by using “Add derived class” option.
5. Assign name “Instrument_BUBBLE”.
6. Now right click on wall penetration copy custom attributes.
7. Paste this custom attributes on Instrument Bubble class.
8. Edit the AutoPLANT class name refers below image.
9. Now, Click On Note and Copy as below
10. Paste like below and add AutoPLANT property Map ‘TAG NUMBER’
11. Save and close schema.
12. Launch OpenPlant Isometrics Manager. Click on configuration button. See image below.
13. Add new label ‘Instrument Bubble’ here.
14. Edit as per below image.
15. Save and close.
16. Generate isometric to review the result.